6. Never allow battery acid to drip on the voltage converter. Medical Equipment Notice Analytic Systems does not recommend the use of their products in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness.
Page 3
• Table of Contents • Description/Overview of product • Main Parts • Operation instructions • Mounting Instructions • Connection instructions • Configuration instructions • Options • Faults • Specifications • Warranty Copyright (2005-2016) Analytic Systems Ware (1993) Ltd. Revised - September 16, 2016...
Introduction The VTC1505 Voltage Convertery provides up to 1500 watts continuous and 1800 watts intermittent to power one or more loads from a 110, 250 or 300 VDC source. Two positive and two negative output connections are provided for easy connection to multiple devices. The recently updated single board design incorporates state of the art switch- mode technology for unmatched efficiency and ultra-quiet operation.
Rear Panel 1. Thermostatically controlled cooling fans x 2 2. Dry Contact Output Fail Relay Connection 3. Remote Control Connection Top of Chassis (not shown) 1. Carrying Handle (Optional) 2. Digital Voltage Current Display (Optional, not shown). Adds three inches to chassis length...
Operation To turn the unit on, simply press the Power push button. The alarm buzzer will sound and the Low Output LED will come on briefly, and then the green OUTPUT ON LED will illuminate. The unit will provide the regulated voltage from no load to the maximum load shown in the specifications section.
Dry Contact Relay The relay is factory preset to fail when the low output LED and buzzer come on. Both normally open and normally closed contacts are available on the connector. If your system detects an alarm condition when the voltage converter is operating normally, simply move the wire connected to Pin 1 of the dry contact terminal block to Pin 3, or vice versa as needed.
Installation Mounting Mount the unit and allow at least 1 inch of clearance around the heat sink fins for adequate cooling. 3.76 0.25 Input Connection 12.00 This unit is equipped with a 1.0 m AWG12 2.39 16.80 cable (approx. length) for connection to the DC power source.
Troubleshooting This unit provides LED indicators and a buzzer to help diagnose any problems. The unit should sound the buzzer to alert you prior to shutting itself down. You should immediately check the indicators to determine the cause of the shutdown. OVERLOAD Indicates that the load connected to the voltage converter exceeds the continuous rating.
2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
Page 12
DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 sales@analyticsystems.com www.AnalyticSystems.com Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way Delta, BC V4G 1K5 | Canada...