3.2.1.1.Pre-identification mode

A pre-identification sensor for all type of cable.
Mode only usable with a transmitter in S1 mode or two transmitters in
S1 and S2 mode.
 Connect the sensor to the receiver, the pre-identification
light illuminates.
 Place the sensor on the cable, so that the groove under the
sensor fits around the cable.
 Press the « measurement » button, the « end of
measurement » light turns off.
 Wait for the result (6 seconds) without moving the sensor,
the « end of measurement » light illuminates and if the
cable is pre-identified, then the YES LED illuminates.
 If the cable is not pre-identified, repeat the operation on
other points of the cable with 10cm of distance between
them.
 If the answer is YES, it is always good to confirm this by
repeating the measurement at several points along the
cable.
The receiver indicates by « YES » the identification of the cable.