Hardware
Component
EtherCAT ERROR
FI error
Link
Speed
X6B
X6C, X6D
Description
Red Led according to specification of ‚ERR Indicator' in the EtherCAT specification
([1]):
Flashing
Constantly OFF
Cyclically blinking with ON(200ms) /
OFF(200ms)
Single flash with ON(200ms) /
OFF(1000ms)
Double Flash with ON(200ms)
/ OFF(200ms) / ON(200ms) /
OFF(1000ms)
Constantly ON
Red Led as a repeater of the Error-Led of the FI control:
Flashing
Constantly OFF
Blinking
Constantly ON
Yellow Led in Ethernet connector:
Flashing
Constantly OFF
Constantly ON
Blinking
Green Led in Ethernet connector: Displays, whether the Ethernet communication
is running with 100Mbit/s (LED = constantly ON) or not.
RJ45 connector of the diagnostic interface.
Attention !!! In order to avoid a destruction of the PC interface, the diagnostic in-
terface may only be connected to the serial interface of the PC by a special HSP5
cable with voltage adaption.
Standard Ethernet-RJ45 connector according to IEEE 802.3 100Base-T
Description
No Error
General configuration errror
The application of the slave device has
automatically changed the communication
state
The application watchdog has responded.
The process data watchdog has respon-
ded. The host controller of the application
does not respond any more.
Description
No power supply on the FI control board
FI control board in error status
Operating condition OK
Description
No Ethernet link present
Ethernet link present
Ethernet communication active
GB - 7
Need help?