PREfaCE Preface The described hard- and software are developments of the KEB Automation KG. The enclosed documents correspond to conditions valid at printing. Misprint, mistakes and technical changes reserved. Signal words and symbols Certain operations can cause hazards during the installation, operation or thereafter.
Copyright The customer may use the instruction manual as well as further documents or parts from it for internal purposes. Copyrights are with KEB Automation KG and remain valid in its entirety. Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their...
2.4 Rear ..............................20 2.4.1 Connectors .........................21 2.4.2 Top Connectors ........................22 2.4.3 RVL - Top Connectors / LED ....................23 2.4.4 KEB Remote Video Link ..................... 24 2.4.5 LED Signaling ........................25 2.4.6 Buttons Area ........................26 2.4.7 Power Supply / Earth Screw ....................27 2.4.8 Battery CR2032 3V ......................
Page 6
5.2 How EWf works ..........................44 5.3 Protectable Volumes ........................44 5.4 KEB EWF configuration ........................ 45 5.5 Delivery state of EWf on KEB devices ..................46 5.6 Using KEB_Wf_Mgr ........................46 5.7 Dependent Volumes ........................48 5.8 Leave the KEB_Wf_Mgr ....................... 50 6 Maintenance and service ..........
Page 7
TaBLE Of CONTENTS 7.2.1 Power supply technical data ....................57 7.2.2 System power consumption ....................58 7.3 Battery technical data ........................58 7.4 Technical support and repairs ..................... 59 8 Certification ..............60 8.1 Mark of conformity ........................60 8.2 UL certifications ..........................62...
LIST Of TaBLES List of Tables Table 1: Micro UPS data ........................30 Table 2: Protectable Volumes ......................44 Table 3: Technical data ........................55 Table 4: Options..........................56 Table 5: Power supply technical data .................... 57 Table 6: System power consumption ..................... 58 Table 7: Battery technical data ......................
FSoE Functional Safety over EtherCAT Universal serial bus Reference potential, ground Hardware fault tolerance Head module Description for the bus coupler or small control in the KEB-I/O EtherCat system Human machine interface (touch screen) International standard IP xx Degree of protection (xx for level)
STaNDaRDS fOR CONTROL & aUTOMaTION Standards for control & automation DGUV regulation 3 Electrical installations and equipment DIN 46228-1 Wire-end ferrules; Tube without plastic sleeve DIN 46228-4 Wire-end ferrules; Tube with plastic sleeve DIN IEC 60364-5-54 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements, protective conductors and protec- tive bonding conductors (IEC 64/1610/CD) DIN VDE 0100-729...
Page 13
STaNDaRDS fOR CONTROL & aUTOMaTION techniques - Surge immunity test (IEC 61000-4-5); German version EN 61000-4-5 EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6); German version EN 61000-4-6 EN 61000-4-34 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase (IEC 61000-4- 34);...
ATTENTION Hazards and risks through ignorance. ► Read the instruction manual ! ► Observe the safety and warning instructions ! ► If anything is unclear, please contact KEB ! 1.1 Target group This manual is written for qualified personnel from construction, project planning, ser- vice and commissioning. Qualified personnel for the purpose of this instruction manual must have the following qualifications: Knowledge and understanding of the safety instructions.
BaSIC SafETy INSTRUCTIONS 1.3 Installation DaNGER Do not operate in an explosive environment! ► The device is not intended for the use in potentially explosive envi- ronment. To prevent damages to the device: • Make sure that no components are bent and/or isolation distances are changed. •...
► The function of electronic devices can be affected by the setting and parameterisation. Never replace without knowledge of the applica- tion. ► Modification or repair is permitted only by KEB Automation KG au- thorized personnel. ► Only use original manufacturer parts. ► Infringement will annul the liability for resulting consequences.
Devices with safety function are limited to a service life of 20 years. Then the devices must be replaced and disposed by way that they do not come into circulation again. Electronic devices of the KEB Automation KG are exclusively professional devices for further industrial processing (so-called B2B devices). Thus the marking does not occur with the symbol of the crossed-out wheeled bin, but by the word mark and the date of manufacture.
C6 E22 BM is a wall book mounting PC designed for installation in industrial control cabinets. C6 E22 BM is based on the Intel® Bay Trail™ SoC (System on chip) platform, with a quad core Celeron J1900 processor 2.0 GHz (2.42 GHz Burst Frequency), cooled by an internal passive sink placed inside the aluminium housing, that enables fanless opera- tion up to 50°C.
SySTEM DESCRIPTION 2.3 front Compact solid and robust full aluminium. Figure 3: Front detail 2.4 Rear The back of the system is made of a full aluminium plate. Fixing holes Rear fixing plate Figure 4: Rear detail...
SySTEM DESCRIPTION 2.4.1 Connectors To access the connectors, it is necessary to open the frontal flap. Front door USB 3.0 connector Battery slot CFAST slot sata2 Opening handle Figure 5: Connector detail...
SySTEM DESCRIPTION 2.4.3 RVL - Top Connectors / LED Battery pack connector Power DC input connector RVL LINK LED RVL OUT LAN1 connector LAN2 connector USB2 connector USB1 connector Figure 7: Top connectors detail (RVL)
2.4.4 KEB Remote Video Link C6 E22 BM-RVL integrates all the circuitry that allows the DVI-D and USB 2.0 signals to be reliably transmitted to a monitor up to 100 m away using a Cat 5e SF/UTP or Cat 6A SFTP (Shield Foil Twisted pair) cable.
SySTEM DESCRIPTION 2.4.5 LED Signaling LED signaling area Figure 10: LED signaling detail Power on LED UPS LED HDD activity LED Over temperature / Battery fault LED Watchdog / Reset factory default LED PLC status LED Bus status LED Figure 11: Buttons area detail...
SySTEM DESCRIPTION 2.4.6 Buttons area Buttons area Figure 12: Buttons area detail Power on rest System reset Watchdog reset Factory default reset PLC Run/Stop/Reset Figure 13: Buttons area detail...
SySTEM DESCRIPTION 2.4.7 Power Supply / Earth Screw Earth screw Power supply area Figure 14: Power Supply area detail Earth screw Figure 15: Power Supply area detail UPS connector Power supply socket Figure 16: Power Supply area detail...
SySTEM DESCRIPTION 2.4.8 Battery CR2032 3V Battery Figure 17: Battery slot detail DaNGER Risk of explosion! If the battery is replaced with an incorrect type. Dispose of used batteries according to the instructions.
Figure 18: CFast slot detail WaRNING Only use KEB approved CFast cards for industrial application. All the CFast cards intended for other uses (digital cameras, consumer products) do not have the endurance, the performance and the security features (as data reliability in case of a sudden power-off) required for an industrial application.
YES, applications can subscribe μUPS “power-down event” form μUPS APIs. lity Note: no shutdown command is sent to the OS, hence no files nor databases can be automatically closed without proper handling of the event. Note: If KEB CONTROL has to manage retain variables the user’s “event- application” must work on a priority level greater than 10. Note: please contact KEB support for further details about APIs availability and use. Software utility Micro UPS diagnostic utility (available on request).
SySTEM DESCRIPTION 2.4.11 Labels position On the lateral panel the following label is present: Model CE marking Material number COMBIVIS connect license COMBIVIS HMI license Figure 19: Labels postion...
3.1 Preparation for installation 3.1.1 Select the mounting location • Avoid direct sunlight ex-posure. • Make sure that C6 E22 BM is properly (ergonomically) accessible to the operator. • Choose a suitable mounting height. 3.2 Checking the package contents •...
INSTaLLaTION aND CONNECTION 3.7 Mounting the device The system can be installed on a panel/wall as follows: Tool required action Cross screwdriver 2.5 mm Screw / unscrew n.4 fixing screws • Drill the required holes on the housing panel/wall according to the instructions detailed in paragraph 3.6 Dimensions. •...
INSTaLLaTION aND CONNECTION • Align the bottom. Figure 25: Wall mounting procedure • Release the top to match the slots with the screws. Figure 26: Wall mounting procedure • Tighten the four screws. Figure 27: Wall mounting procedure...
The data cable screens connecting the equipment’s chassis on one end and the C6 E22 BM chassis on the other end can therefore be subject to a high current circulation capable of destroy- ing the interface.
Figure 30: Grounding detail • Tighten the four screws. 3.8.1 Power supply insolation The C6 E22 BM power supply is galvanically isolated which means its output is electri- cally separated from its input. This feature has many benefits: • Increases the noise immunity of the system. • Avoids input short circuits in systems with the power supply grounded.
INSTaLLaTION aND CONNECTION Figure 31: Power supply connection detail 3.8.3 Power connection assembly The system is equipped with a connector cup to be installed on the two poles power connector. To properly assemble the connector please follow these instructions: Figure 32: Power connector assembly •...
INSTaLLaTION aND CONNECTION • Place the two poles plug connector in the cup as shown in the picture. Figure 35: Power connector assembly • Tighten the cable tie. Figure 36: Cup installation • Cut the excess part. Figure 37: Cup installtion •...
INSTaLLaTION aND CONNECTION • Example of a correctly installed cup. Figure 39: Power connector assembly 3.8.4 Power on The system has to be connected to a 24 V (18-32V) power supply which satisfies the requirements of safe extra low voltage (SELV) in accordance with IEC/EN/DIN EN/ UL60950-1. • Remove the two poles plug connector from the system (the system is shipped with the power plug connected).
INSTaLLaTION aND CONNECTION • Connect the positive and the negative poles (also refer to the label on the back of the system) to their respective terminals of the two pole plug connector. Use wires with a cross-section of 1.5 mm (AWG16).
SySTEM STaRT-UP 4 System Start-up 4.1 additinal notes for Windows Embedded Standard 7 KEB has created a Windows Embedded Standard 7 images that support a set of “Em- bedded Features” (for example Enhanced Write Filter), not present in Windows 7. 4.2 EWf implementation in the Windows Embedded Standard 7 images The KEB Windows Embedded Standard 7 images have a built-in support for Enhanced Write Filter (EWF).
KEB WRITE fILTER MaNaGER 5 KEB Write filter Manager 5.1 Introduction KEB Write Filter Manager (KEB-WF_Mgr) bases on the Enhanced Write Filter (EWF) from Microsoft for Windows Embededd Standard 7 (WES7). 5.2 How EWf works EWF protects a volume from write access. This is realized by an EWF Overlay: EWF protects the contents of a volume by redirecting all write operations to another storage location.
KEB WRITE fILTER MaNaGER 5.4 KEB EWF configuration On KEB devices RAM overlay is used and the EWF configuration is stored in the regis- try of the WES7 operating system, which resides with the operating system on volume C:\. This implies that changes to the EWF configuration are only possible if the EWF for volume C:\ is disabled or the changes to C:\ will be committed. Otherwise they will be discarded after a reboot.
KEB WRITE fILTER MaNaGER 5.5 Delivery state of EWf on KEB devices On KEB Windows Embedded Standard 7 image, EWF is disabled by default at shipment because some settings have to be made on the device respective in the registry by the user (e.g.
EWF for volume C:\has been enabled by the message box already before). Figure 46: Program’s GUI Under the Volume you see the states of the selected volume as read-only fields: • Overlay Type: On KEB devices always RAM-REG. • EWf Status: Current status of the EWF. • EWf Boot: Command which will be performed with the next reboot.
KEB WRITE fILTER MaNaGER On the right side you see the EWF Control commands, each with a help button aside (the commands which are not available in the current constellation are greyed and di- sabled): • Enable: Enables a currently disabled overlay on the specified EWF-protected volu- me. This function requires a reboot.
KEB WRITE fILTER MaNaGER Figure 47: Commit • Commit: This command is independent from volume C:\ because the status of E:\ (EWF disabled) is untouched. But Commit needs a reboot to become effective. • Commit Disable live: The command commits and disables immediately. To keep the EWF for the volume disabled after reboot a “Commit” to volume C:\ is necessary.
KEB WRITE fILTER MaNaGER 5.8 Leave the KEB_Wf_Mgr A Shutdown or Reboot of the device can be initiated directly from the KEB_WF_Mgr to take effect for pending boot commands by using the particular buttons. The program can also be left by the Exit button. In this case the program checks for...
MaINTENaNCE aND SERVICE 6 Maintenance and service 6.1 Battery installtion / removal Tool required action Pull the battery holder. Plastic screwdriver • Turn off the system and disconnect the power supply. • Using a screwdriver (not provided) carefully pull out the battery holder. Figure 51: Battery installation / removal Figure 52:...
Extract the memory card from the slot. 6.3 Maintaining and cleaning C6 E22 BM is designed for maintenance-free operation except for the replacing of the battery backup when necessary. It is recommended to clean the touchscreen with a damp cleaning cloth and a display cleaning solution.
Suedstrasse 38 32683 Barntrup, Germany telephone +49 5263 401-0 fax +49 5263 401-116 e-mail: COMBICONTROL@keb.de 6.5 Recycling and disposal C6 E22 BM can be recycled due to the use of materials with low environmental impact. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices.
Front signaling (LED) Power ON ▪ Micro UPS ▪ Over temperature / Battery fault ▪ Watchdog / Reset factory default ▪ PLC status ▪ BUS status Front buttons (with open door) Power ON ▪ System Reset ▪ Watchdog Reset ▪ Factory Default Reset On Top I/F C6 E22 BM 2 x Ethernet 10/100/1000 Mbps (RJ45), Intel® I210 ▪ 2 x USB 2.0 (Type A) ▪ 1 x DVI-I Single Link (max risolution: DVI-D/VGA 1920x1080 FullHD) On Top I/F C6 E22 BM-RVL 2 x Ethernet 10/100/1000 Mbps (RJ45), Intel® I210 ▪ 2 x USB 2.0 (Type A) ▪ 1 x RJ45 (RVL OUT) remotation (TX) of DVI-D video sig-...
DVI-I (Single Link) video interface for additional external ● monitor ▪ Max resolution 1920x1080 FullHD ▪ VGA ad- apter included External Monitor Output Remote Video Link integrated ▪ remotation up to 100m ● of DVI-D video signals and USB 2.0 ▪ without cables > note 1 Table 4: Options Note 1 C6 E22 BM-RVL has to be used with a C6 Monitor or C6 AMM that integrates the RVL module (Remote Video Link).
TECHNICaL SPECIfICaTIONS 7.2.1 Power supply technical data The power supply board is provided with a FAST FUSE 4A SMD. The fuse can be replaced only in factory. Power supply Type Isolated DC-DC Isolation voltage 500 VAC Input voltage 18÷32V DC Input protection Reverse polarity circuitry Overvoltage...
I210 Table 6: System power consumption Note 1 C6 E22 BM-RVL has to be used with a C6 Monitor or C6 AMM that integ- rates the RVL module (Remote Video Link). 7.3 Battery technical data Figure 58: Battery CR2032 detail...
Figure 60: Battery dimensions 7.4 Technical support and repairs KEB offers wide-ranging, complete after-sales technical support. The staff who deal with this handle questions on the entire range of products skilfully, quickly, and efficiently. You can phone our staff in the service department, and they will give you complete, prompt advice on how to resolve your problems.
The original EC-Declaration of Conformity and the associated documentation can be made available to the competent authorities. Please contact the Product Management, as necessary. Document No. / month.year: ce_ca_remv-C6H-a_en / 01.2018 Manufacturer: KEB Automation KG Südstraße 38 32683 BARNTRUP Germany Product type Control type xx –...
CERTIfICaTION 8.2 UL certifications Acceptance according to UL is marked at KEB inverters with the adjacent logo on the type plate.
Page 63
Room 1709, 415 Missy 2000 725 Su Seo Dong Gangnam Gu 135- 757 Seoul Republic of Korea Société Française KEB SASU Tel: +82 2 6253 6771 Fax: +82 2 6253 6770 E-Mail: vb.korea@keb.de france Z.I. de la Croix St. Nicolas 14, rue Gustave Eiffel 94510 La Queue en Brie France KEB RUS Ltd.