1.3.e Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
NOTICE
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
l
damage the heat pump. This will not be covered under equipment warranty.
MODEL
SQ120R
SQ125
SQ145
SQ166R
SQ225
T035
T055
T075
T090
T115
T135
PLEASE NOTE -
If minimum flow rates are not met, heat pump performance is reduced and performance will
suffer. Internal safety devices may deactivate the heat pump with the following errors:
HP and HP5
l
or (if equipped) error codes of LP and LP5
l
Operate water filtration devices per manufacturer's specifications. Dirty filters can cause a reduction of water flow
l
to the heat pump. An increase of 7-10 psi higher than the clean filter pressure typically reduces flow rates. This
requires the filter to be cleaned or back-washed.
Keep baskets free of debris. A large quantity of debris in the pump and skimmer baskets can reduce water flow.
l
Check for improper valve settings. A partially closed valve after the filter, or a full-open bypass around the heat
l
pump, will cause insufficient water flow through the heat pump.
The maximum static pressure (or operating pressure) is 50 pounds-per-square-inch (PSI). These specifications
l
relate to the heat pump only.
Code-specified whole system turnover rates must be satisfied.
l
Page - 9
Failure to heed the following may result in damage to equipment.
HEAT EXCHANGER TYPE
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium Tube-in-Tube
Titanium Tube-in-Tube
Titanium Tube-in-Tube
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
FLOW RATES
MINIMUM MAXIMUM
®
30 GPM
®
30 GPM
®
30 GPM
®
30 GPM
®
30 GPM
20 GPM
20 GPM
20 GPM
®
30 GPM
®
30 GPM
®
30 GPM
70 GPM
70 GPM
70 GPM
70 GPM
70 GPM
45 GPM
45 GPM
45 GPM
70 GPM
70 GPM
70 GPM