4.1.b Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
CAUTION - Failure to heed the following may result in equipment damage.
Water flow exceeding maximum flow rate may damage heat exchanger; such damage will not be covered under
l
the equipment warranty
MODEL
SQ120R
SQ125
SQ145
SQ166R
SQ225
T035
T055
T075
T090
T115
T135
CHEMISTRY LEVEL CHART
(RESIDENTIAL)
POOLS
1.0 – 3.0 ppm 3.0 – 5.0 ppm
2.0 – 6.0 ppm 2.0 – 6.0 ppm
30 - 50 ppm
30 - 50 ppm
7.4 – 7.6 ppm 7.4 – 7.6 ppm
80 – 120 ppm 80 – 120 ppm
200 – 400
150 – 250 ppm
ppm
1,500 ppm above start-up total dissolved solids in
0 – 1,500 ppm
spas
HEAT EXCHANGER TYPE
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
Titanium Tube-in-Tube
Titanium Tube-in-Tube
Titanium Tube-in-Tube
Titanium ThermoLink
Titanium ThermoLink
Titanium ThermoLink
SPAS
FLOW RATES
MINIMUM MAXIMUM
®
30 GPM
®
30 GPM
®
30 GPM
®
30 GPM
®
30 GPM
20 GPM
20 GPM
20 GPM
®
30 GPM
®
30 GPM
®
30 GPM
70 GPM
70 GPM
70 GPM
70 GPM
70 GPM
45 GPM
45 GPM
45 GPM
70 GPM
70 GPM
70 GPM
Page - 9