EFI Vutek QS2000 Operator's Manual page 59

Table of Contents

Advertisement

4 Dispose of the old waste tank and its contents in a
5 Ensure the waste tank's vent hole cap is removed and the
6 Insert the float switch assembly into the new waste tank
Cleaning the static eliminator bars
In order for the static eliminator bars to operate at optimum
efficiency, they must be cleaned on a monthly basis to remove
dust and debris. The static eliminators may need to be
cleaned more regularly, depending upon the operating
environment and types of media used.
1. From the VUTEk User Interface Service menu, click
2. Turn off the UV lamp system.
3. Turn off the static bar power supply located at the back
4. Using a small brass bristled brush, lightly brush along
5. Vacuum the slot to remove any remaining debris.
6. Use an inspection mirror to inspect the pins, they should
7. Repeat steps 3 through 6 for the static bar on second lamp
OMM-00038-US English-F
manner consistent with your local safety and
environmental regulations.
hole is open.
and screw the cap on.
Service Aids. From the Service Aids dialog box
Carriage Maintenance Positions section, click
Maintenance to move the carriage to the maintenance
position.
In the UV Lamp Control Diagnostics dialog box, click
Stop Lamps ( ).
and on top of the carriage.
The switch lights up red when it is on.
the slot containing the sharp pins (underneath the bar),
until the slot and the pins are free from dust and dirt.
be sharply pointed and free of debris.
housing.
QS Series Basic Operator's Guide
53