Setting The Hand-Held Reader/Writer - Omron V680 series User Manual

Hand-held reader writer. rf tags
Hide thumbs Also See for V680 series:
Table of Contents

Advertisement

Setting the Hand-held Reader/Writer

Settings
The following settings are used to operate the Hand-held Reader/Writer.
• Serial communications parameters (baud rate, transmission code, parity check, stop bits)
• Basic function settings (Auto Command OFF)
These settings can be changed by sending a setting command from the host device. To operate the
Hand-held Reader/Writer with the new setting, the power must be turned OFF then ON again, or the
ABORT command must be used.
 Serial Communications Parameters
The following settings are related to serial communications. Use the COMMUNICATIONS CONDI-
TIONS SETTING (TR) command.
Item
Baud rate (bps)
Transmission code
Parity check
Stop bits
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
 Basic Function Settings
The Auto Command OFF function can be set. Use the BASIC FUNCTIONS SETTING (FN) command.
Item
Auto Command OFF function
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
Reading the Settings
Use the SET INFORMATION READ (UL) command to read the settings of the Hand-held Reader/
Writer. The information read by the SET INFORMATION READ command is set in the backup memory
of the Hand-held Reader/Writer. For this reason, care must be taken when the power is first turned ON
after the settings have been changed because the operational settings of the Hand-held Reader/Writer
will be different.
2,400, 4,800, 9,600*, 19,200, 38,400
7-unit ASCII 7* or 8-unit JIS 8
Even parity*/odd parity/none
2*/1
Yes (1 minute)*, No