Setting the Hand-held Reader/Writer
Settings
The following settings are used to operate the Hand-held Reader/Writer.
• Serial communications parameters (baud rate, transmission code, parity check, stop bits)
• Basic function settings (Auto Command OFF)
These settings can be changed by sending a setting command from the host device. To operate the
Hand-held Reader/Writer with the new setting, the power must be turned OFF then ON again, or the
ABORT command must be used.
Serial Communications Parameters
The following settings are related to serial communications. Use the COMMUNICATIONS CONDI-
TIONS SETTING (TR) command.
Item
Baud rate (bps)
Transmission code
Parity check
Stop bits
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
Basic Function Settings
The Auto Command OFF function can be set. Use the BASIC FUNCTIONS SETTING (FN) command.
Item
Auto Command OFF function
Note: Items marked by an asterisk (*) are set as the default when shipped from the factory.
Reading the Settings
Use the SET INFORMATION READ (UL) command to read the settings of the Hand-held Reader/
Writer. The information read by the SET INFORMATION READ command is set in the backup memory
of the Hand-held Reader/Writer. For this reason, care must be taken when the power is first turned ON
after the settings have been changed because the operational settings of the Hand-held Reader/Writer
will be different.
2,400, 4,800, 9,600*, 19,200, 38,400
7-unit ASCII 7* or 8-unit JIS 8
Even parity*/odd parity/none
2*/1
Yes (1 minute)*, No
Communications Preparations
Contents
Contents
Section 2
RFID System
49