Standard System Adjustments; Setting The Motor Limits; Out Limit Switch - Carefree APEX Service Manual

With direct response electronics rv
Hide thumbs Also See for APEX:
Table of Contents

Advertisement

APEX
S
S
TANDARD
YSTEM
S
M
ETTING THE
OTOR
The "
" limit switch stops the motor when the awning is fully extended. The "
OUT
motor when the awning is fully retracted. The "
The limit switches are located
inside the case, near the end
plate.
To access the switches:
Increase
Run Time
Decrease
Run Time
Configuration 1
(Discontinued)
Increase
Run Time
Decrease
Run Time
Configuration 2
(Inactive)
Decrease
Run Time
Increase
Run Time
Configuration 3
(Current)

OUT Limit Switch

1. Extend the awning out completely.
2. Confirm that the arms are fully extended. The motor should stop and the fabric should be tight. If the
motor continues to run, the fabric will sag; or, if the motor quits before the arms are fully extended, it will
be necessary to adjust the "
NOTE: It is best to make the adjustments in increments of a single turn. 3 full turns of the screw
equals approximately 2" of fabric extension.
3. If the fabric sags:
3.1. Retract the awning until the fabric is tight then retract an addition 10"-12".
3.2. Using a 4mm Allen wrench turn the "
3.3. Extend to confirm that the adjustment is correct.
3.4. Repeat the procedure until the awning extends correctly.
4. If the arms do not extend completely:
4.1. Retract the awning approximately 10"-12".
4.2. Using a 4mm Allen wrench turn the "
4.3. Extend to confirm that the adjustment is correct.
4.4. Repeat the procedure until the awning extends correctly.
2
Service Manual
A
DJUSTMENTS
L
IMITS
" limit is
IN
Rotate
Remove
Cover
Cover Screws
Remove
End Caps
Units Built
Before June 2005
NOTE: There are three (3) motor limit switch configurations.
Visually inspect the limit switches to determine which
configuration is installed in the awning. Use the illustrations
to determine the correct turning direction for adjustments.
"OUT"
Limit Switch
4mm Allen Head
"IN"
Limit Switch
4mm Allen Head
Lead Rail
LH Motor
The limit switches are located inside the case, near the end plate.
To access the switches, remove the rubber plugs on top of the
case next to the end plate.
" limit switch.
OUT
" limit switch to reduce the time the motor runs.
OUT
" limit switch to increase the time the motor runs.
OUT
with the Direct Response system.
NOT USED
Rotate
Remove
Cover
Cover
Screw
"IN"
Limit Switch
4mm Allen Head
"OUT"
Limit Switch
4mm Allen Head
RH Motor
Carefree of Colorado
" limit switch is used to stop the
IN
Manual Override
Plug (ref)
Remove
Limit Switches
Plugs
Lead Rail
Increase
Run Time
Decrease
Run Time
Configuration 1
(Discontinued)
Increase
Run Time
Decrease
Run Time
Configuration 2
(Inactive)
Decrease
Run Time
Increase
Run Time
Configuration 3
(Current)
052522-301r11
RTA014b
Paramount014

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents