3. OPERATION PROCEDURE

3.1. Controls and Indicators

The location of controls, indicators and connectors is shown in Figures 1.1 and 1.2. These
elements have the following functions:
а) socket for mains supply is intended for the Analyzer connection to power supply line using
the power supply cord;
b) fuse-holder is intended for inserting 2 fuses;
c)
mains switch turns the power of the Analyzer on/off;
d) additional grounding connector ensures the Analyzer grounding in case the primary power
supply line does not have a protective grounding loop;
e) POWER indicator shows that the Analyzer is switched on;
f)
ETHERNET connector is intended for the Analyzer connection to LAN;
g) RS-232 connector is intended for configuring and updating the Analyzer firmware from an
external PC;
h) RF IN connector is used for the test signal input via F-male connector.

3.2. Preparation for Measurements

Before you start operating your CIU-003, make sure to carefully read this Operating Manual as
well as to inspect the location of the controls and indicators of the Analyzer (see Section 3.1).
To prepare your Analyzer for operation, proceed as follows:
a) make sure that two proper fuses are inserted into the fuse-holder;
b) ground the Analyzer using the additional grounding connector (if the primary power supply
line does not have a protective grounding loop);
c) connect the Analyzer to the 220 V AC circuit via power supply cord;
d) turn the Analyzer on;
e) configure the Analyzer for operation in the LAN by using an external PC (see Section 3.3);
f) connect the Analyzer to the LAN and establish the connection with the ViewRSA software
(see ViewRSA operating manual).

3.3. Analyzer Configuration by PC

3.3.1. General Information

You can use the mode of CIU-003 configuration by PC to perform the following procedures:
a) set and view the following CIU-003 parameters in the LAN: device MAC address, IP address,
subnet mask, and IP address of the network gateway;
b) view the information about your Analyzer: hardware and firmware version, serial number,
current date and time;
c) self-test the Analyzer;
d) set and view ViewRSA connection mode: ViewRSA server IP-address and port.

3.3.2. Connection to Configuration Terminal

The Analyzer setting is performed with Microsoft HyperTerminal or similar software via the
COM port. To configure HyperTerminal software for operation with the Analyzer, proceed as
follows:
a) connect the Analyzer to a free COM port of the PC and turn it on;
b) run HyperTerminal on your PC: