Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 1.2 error.
Name:
Indicator of MPEG stream error: sections with table_id 0x00 do not appear at
least every 0.5 sec on PID 0x0000;
sections with table_id other than 0x00 found on PID 0x0000;
Scrambling_control_field not 00 for PID 0x0000 (ETSI TR101290 1.3a)
Node:
mpeg_PAT_error (1.3.6.1.4.1.32108.2.2.3.4.1.19)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 1.3a error.
Name:
Indicator of MPEG stream error: incorrect packets order; A packet occurs more
than twice; Lost packets (ETSI TR101290 1.4)
Node:
mpeg_Continuity_count_error (1.3.6.1.4.1.32108.2.2.3.4.1.20)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 1.4 error.
Name:
Indicator of MPEG stream error: sections with table_id 0x02 do not occur every
0.5 sec on each program_map_PID which is referred to in the PAT;
scrambling_control_field not 00 for all packets containing information of sections
with table_id 0x02 on each program_map_PID which is referred to in the PAT
(ETSI TR101290 1.5a)
Node:
mpeg_PMT_error (1.3.6.1.4.1.32108.2.2.3.4.1.21)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 1.5a error.
Name:
Indicator of MPEG stream error: one of PID streams does not appear at least
every 5 sec (ETSI TR101290 1.6)
Node:
mpeg_PID_error (1.3.6.1.4.1.32108.2.2.3.4.1.22)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 1.6 error.
Name:
Indicator of MPEG stream error: transport_error_indicator in TS-header is set to 1
(ETSI TR101290 2.1)
Node:
mpeg_Transport_error (1.3.6.1.4.1.32108.2.2.3.4.1.23)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.1 error.
Name:
Indicator of MPEG stream error: CRC error detected in CAT, PAT, PMT, NIT, EIT,
BAT, SDT or TOT table (ETSI TR101290 2.2)
Node:
mpeg_CRC_error (1.3.6.1.4.1.32108.2.2.3.4.1.24)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.2 error.
Name:
Indicator of MPEG stream error: time interval between two consecutive PCR
values more than 40 ms (ETSI TR101290 2.3a)
Node:
mpeg_PCR_repetition_error (1.3.6.1.4.1.32108.2.2.3.4.1.25)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.3a error.
Name:
Indicator of MPEG stream error: the difference between two consecutive PCR
values is outside the range of 0...100 ms without the discontinuity_indicator_set
(ETSI TR101290 2.3b)
Node:
mpeg_PCR_discontinuity_error (1.3.6.1.4.1.32108.2.2.3.4.1.26)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.3b error.