Name:
Indicator of MPEG stream error: PCR accuracy of one of the programs is not
within ±500 ns (ETSI TR101290 2.4)
Node:
mpeg_PCR_accuracy_error (1.3.6.1.4.1.32108.2.2.3.4.1.27)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.4 error.
Name:
Indicator of MPEG stream error: packets with transport_scrambling_control not 00
present, but section with table_id = 0x01present; Section with table_id other than
0x01 on PID 0x0001 (ETSI TR101290 2.6)
Node:
mpeg_CAT_error (1.3.6.1.4.1.32108.2.2.3.4.1.28)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.6 error.
Name:
Indicator of analog channel audio broadcasting disappearing.
Node:
sound_error (1.3.6.1.4.1.32108.2.2.3.4.1.29)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check if a channel passed the limit test by the following test criteria: analog
channel audio broadcasting is present.
Traps
Name:
Device calibration error
Node:
tCalibrationError (1.3.6.1.4.1.32108.2.2.4)
Trap number:
1
Additional
-
nodes
Description:
Sent if device calibration error is detected (usually shortly after the device is
switched on). This error can affect the accuracy of channel parameters
measurements.
Name:
Device hardware error
Node:
tHardwareError (1.3.6.1.4.1.32108.2.2.4.2)
Trap number:
1
Additional
InfoHardware
nodes
Description:
Sent if device hardware error is detected or after the device returns to normal
operation. InfoHardware node contains the information about the hardware error.
Example:
Trap tHardwareError (tuner error):
InfoHardware
Trap tHardwareError (return to normal operation):
InfoHardware
Name:
Device temperature error
Node:
tTemperatureSeverity (1.3.6.1.4.1.32108.2.2.4.4)
Trap number:
1
Additional
Temperature, InfoTemperature
nodes
Description:
Sent if the device temperature is beyond the allowed range of -10 to +50
the temperature returns to the allowed range. Temperature error affects the
accuracy of level measurements. Temperature node shows the current
temperature value, and InfoTemperature contains the data about temperature
error.
Example:
Trap tTemperatureSeverity (temperature value beyond allowed range):
Temperature
InfoTemperature
tuner\
Ok
60
out of range!
29
0
C or after