3.5.2. Description of CIU-003 Branch in MIB-2 Tree

CIU-003 TV Signal Analyzer branch has the following identification number in MIB-2 tree:
1.3.6.1.4.1.32108.2.2. By using this branch, you can perform the following actions:
a) view the device information: serial number, firmware and hardware versions;
b) select and view the name of the monitored network node;
c) control the measurement process: change the measurement interval, start and stop the
measurement process;
d) view and set time and date of the Analyzer;
e) restart the Analyzer;
f) set the IP addresses of trap recipients (up to 3 addresses);
g) view the Analyzer channel plan parameters: channel name, channel type and frequency;
h) view the last measurement results for each channel: signal level, video/audio ratio,
signal/noise ratio, MER value, BER value before and after Reed-Solomon decoder;
i)
view the results of the last limit test;
j)
check current temperature inside the Analyzer;
k) receive the traps from the Analyzer with the following data: firmware and hardware errors of
the device, temperature errors (when temperature value is beyond the allowed range), and
also the results of channel measurement, which failed the limit test.
You can find the list of all CIU-003 branch nodes and more detailed information about them in
the Appendix.

3.6. Updating Firmware

You can update the firmware of CIU-003 TV Signal Analyzer without use of any additional
equipment. We go on with development of the devices and keep on working out new firmware
versions that provide new features. These new firmware versions are available for free download
on our website
www.planar.chel.ru
the firmware has its unique identification number, e.g. 14.0.0.3. You can see the current device
firmware version in configuration terminal window (see Section 3.3.5), by using ViewRSA and also
in the SoftVersion node if you operate the Analyzer via SNMP protocol (see Appendix).
You should proceed as follows to update your firmware:
a) connect your Analyzer to a free COM port of the PC by using a standard cable;
b) create a new folder on your PC for new firmware, e.g. CIU003_Update. Copy
CIU002_SoftLoader installer-program into this folder from our website. CIU002_SoftLoader
requires WindowsXP or Windows Vista operating system. It provides communication with the
Analyzer and downloads new firmware onto it;
c) download new firmware into CIU003_Update folder from our website (file name contains the
number of program version with .bsk extension, e.g. 14_0_0_3.bsk) and copy the file describing
changes to the firmware (file with .txt extension);
d) start CIU002_SoftLoader on your PC (see Figure 3.19). Select COM port of PC, which
connects it to your CIU-003;
e) select the file with new version of CIU-003 firmware by clicking button for file opening (index
1 in Figure 3.19). Find the required file in the standard file selection dialog and click ОК;
f) click Start and follow the instructions of the program. First, a warning notice will appear
advising you to power off your CIU-003 Analyzer and check the connection of the cable to the PC
COM port. Then another data window will appear; follow its instructions.