ABB SpiritIT Flow-X Instruction Manual page 37

Table of Contents

Advertisement

S P I R I T
Signal
V1 Nr
Sphere detector inputs
4
2
Communication
Serial
2
Ethernet
2
Table 9-2 Flow-module I/O Specifications
NOTES:
(1) Total number of analog inputs + HART inputs = 6
(2) Total number of digital inputs + digital outputs + pulse outputs + density inputs + sphere detector inputs = 16
Liquid calculations
API 5, 6, 23, 24, 53, 54, 59 and 60 tables (A.B. D and E)
API 11.1 1980 (API 2540) and 2004/2007
API 1952 historical tables
API 11.2.1, 11.2.2, 12.2, 21.1, 21.2
API 11.3.2.1 Ethylene (API-2565)
GPA TP15, TP16, TP25, TP27
Propylene (API 11.3.3.2)
Butadiene (ASTM D1550)
Asphalt (ASTM D4311)
Ethylene (IUPAC 1988, NIST 1045, API 2565)
Carbon dioxide (NIST)
OIML R22
Gas calculations
AGA3, AGA5, AGA7, AGA8 (Part 1 and 2), AGA9, AGA10, AGA11
AGA-NX19
SGERG-88 and SGERG 2015
GERG-2008
GPA 2172 and GPA 2145
IAPWS-IF97 (steam and water)
ISO 6976 (all editions)
Gas viscosity
GSSSD MR113
Flow calculations
ISO 5167 (all editions)
ISO/TR15377
ISO 6976
AGA3
GOST 8-586
V-cone
Table 9-3 Flow and fluid property calculations
Metering functions
Retroactive meter factors, batch recalculations (meter factor, BS&W, density, etc.)
Unlimited number of period and batch totals and flow and time weighted averages. Periods can be of any type. Maintenance totalizers are supported
Calibration curve up to unlimited number of points (linear and polynomial).
Prover support: uni-directional, bi-directional (2 / 4 detector inputs), compact prover, master meter, dual chronometry, pulse interpolation.
Control functionality:
Flow and pressure control
Valve control
Batching / liquid loading control
Sampling control
API 21.1 and 21.2 compliant
All common spreadsheet functions to obtain maximum flexibility.
Table 9-4 Metering functions
I T
F L O W - X I N S T R U C T I O N M A N U A L | I M / F L O W X - E N
V2 Nr
Type
Description
4
2
High impedance
Supports 1, 2, 3 and 4 detector configurations mode
0.05 μs detect update rate.
2
RS485/422/232
Multi-purpose serial communication interface
Minimum 300 baud, maximum 256000 baud
2
RJ45
Ethernet interface - TCP/IP
100 Mbit/s
3 7