Toshiba RAV-GM 801UT-E Service Manual page 87

Split type, outdoor unit
Table of Contents

Advertisement

(1)-3. Sensor, current, compressor operation frequency, PMV opening indication
Interface (CDB) P.C. board detected values (for example temperature and current sensor values) can be
easily checked.
∗ Temperature sensors ... TD, TE, TL, TS, TO, TH, TA, TC, TCJ
∗ Current ......................... Current sensor (CT) value detected
LED indication
D800
D801
D802
D803
(YEL)
(YEL)
(YEL)
(YEL)
: Go ON
: Go OFF
Temperature
sensor
D804
D805
(˚C)
(YEL)
(GRN)
Less than -25
-25 ~
-20 ~
-15 ~
-10 ~
-5 ~
0 ~
5 ~
10 ~
15 ~
20 ~
25 ~
30 ~
35 ~
40 ~
45 ~
50 ~
55 ~
60 ~
65 ~
70 ~
75 ~
80 ~
85 ~
90 ~
95 ~
100 ~
105 ~
110 ~
115 ~
120 ~
Sensor trouble
: flashing (1 time/sec)
Compressor
Current
frequency
(A)
(rps)
0 ~
0 ~
1 ~
5 ~
2 ~
10 ~
3 ~
15 ~
4 ~
20 ~
5 ~
25 ~
6 ~
30 ~
7 ~
35 ~
8 ~
40 ~
9 ~
45 ~
10 ~
50 ~
11 ~
55 ~
12 ~
60 ~
13 ~
65 ~
14 ~
70 ~
15 ~
75 ~
16 ~
80 ~
17 ~
85 ~
18 ~
90 ~
19 ~
95 ~
20 ~
100 ~
21 ~
105 ~
22 ~
110 ~
23 ~
115 ~
24 ~
120 ~
25 ~
125 ~
26 ~
130 ~
27 ~
135 ~
28 ~
140 ~
29 ~
145 ~
30 ~
150 ~
31 or more
155 or more
– 87 –
Degree of PMV
opening
(pls)
0 ~ 19
20 ~ 39
40 ~ 59
60 ~ 79
80 ~ 99
100 ~ 119
120 ~ 139
140 ~ 159
160 ~ 179
180 ~ 199
200 ~ 219
220 ~ 239
240 ~ 259
260 ~ 279
280 ~ 299
300 ~ 319
320 ~ 339
340 ~ 359
360 ~ 379
380 ~ 399
400 ~ 419
420 ~ 439
440 ~ 459
460 ~ 479
480 ~ 499
500

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents