4-Way Cassette <Twin Type - Toshiba RAV-GM 801UT-E Service Manual

Split type, outdoor unit
Table of Contents

Advertisement

1-1-4. 4-Way Cassette
<Twin type>
Model
Cooling capacity
Heating capacity
Power supply
Cooling Running current
Electrical
Heating Running current
characteristics
Fan
Fan unit
Standard air flow (H/M+/M/L+/L)
Motor
Sound pressure level
Sound power level
Max total length
Min length
Outer dimension
Height
difference
Fan
Fan unit
Standard air flow high
Motor
Outdoor unit -
Pipe branch
Connecting pipe
Pipe branch-
indoor unit
Sound pressure level
Sound power level
Indoor unit1
RAV-RM
Outdoor unit
RAV-RM
Indoor unit2
Power consumption
Power factor
EER
SEER
Energy efficiency class (Lot10)
Power consumption
Power factor
COP
SCOP
Energy efficiency class (Lot10)
Maximum current
(H/M+/M/L+/L)
(H/M+/M/L+/L)
Outdoor lower
Outdoor high
Gas side
Liquid side
Gas side
Liquid side
Cooling/Heating
Cooling/Heating
561UTP-E
561UTP-E
RAV-GP
1101AT-E
(kW)
10.0
(kW)
11.2
Indoor unit
(A)
10.19-9.34
(kW)
2.13
(%)
95
4.69
8.57
A++
(A)
11.20-10.26
(kW)
2.34
(%)
95
4.79
4.73
A++
(A)
20.5
turbo fan
3
(m
/min)
17.5/-/14.5/-/13.0
(W)
14
(dB-A)
32/-/29/-/28
(dB-A)
47/-/44/-/43
Outdoor unit
(m)
75
(m)
3
(m)
30
(m)
30
Propeller fan
3
(m
/min)
116
(W)
100+100
(mm)
15.9
(mm)
9.5
(mm)
12.7
(mm)
6.4
(dB-A)
49/50
(dB-A)
66/67
– 20 –
801UTP-E
801UTP-E
1401AT-E
1phase 220-240V/50Hz
15.12-13.86
15.36-14.08
turbo fan
20.5/-/16.0/-/13.5
35/-/31/-/28
50/-/46/-/43
Propeller fan
100+100
50/51
67/68
12.5
14.0
3.16
95
3.96
8.14
3.21
95
4.36
4.72
20.7
20
75
3
30
30
116
15.9
9.5
15.9
9.5

Hide quick links: