10

Power

The unit is designed to be powered by 24 V DC.
It is protected against reverse polarity, under voltage and over voltage (for a limited
duration).
A fuse or circuit breaker should be fitted to the positive supply. For recommended fuse
rating, refer to "Technical specifications" on page 17.
Power connector details
1
2
Unit socket (male)
Pin
Purpose
1
+12/24 V DC
2
DC negative

Serial

The serial port provides input (Listeners) and outputs (Talkers) for the various interfaced
sensors. The port uses the IEC 61162 (serial balanced) standard.
IEC 61162 messages
For details about how to configure the serial ports, refer to the commissioning manual.
Sentence
Description
THS
True heading
status
HDT
Heading true
VDM
AIS VHF data-link
message
VDO
AIS VHF data-link port 2 in
TTD
Tracked target
data
TLB
Target label
VBW
Dual ground/
water speed
VHW
Water speed and
heating
ZDA
Time and date
GLL
Geographic
position-
latitude and
longitude
GGA
Global
positioning
system (GPS) fix
data
Wiring
| R5000 radar processor Installation Manual
Cable plug (female)
Standard
BAM
port 1 in
port 1 in
port 1 in
port 1 in
port 2 in
port 2 in
port 2 in
port 2 out
port 2 out
port 2 out
port 2 out
port 3 in
port 3 in
port 3 in
port 3 in
port 4 in
port 4 in
port 4 in
port 4 in
port 4 in
port 4 in
1
2
Legacy alert
port 1 in
port 1 in
port 2 in
port 2 in
port 2 out
port 2 out
port 3 in
port 3 in
port 4 in
port 4 in
port 4 in