1. IDENTIFYING SUPPLIED PARTS
Unpack and check the contents. If any of these parts are missing, contact your distributor.
Main Unit (1ea)
Keypad(Option)
2. RECOMMAND CABLE TYPE AND PERMISSIBLE LENGTH
Reference
①
②
*
③
④
⑤
⑥
* Requires thicker wire if you connect the reader with high current consumption.
Quick Guide (1copy)
LCD Module(Option)
Description
iCON100 Power (DC12V)
DC Power -> iCON100
Reader (Power and Data)
Extra Reader
Door Contact
Exit Button
Sensor Input
Input -> iCON100
Door Lock,
Alarm Device
Lock (Alarm) -> iCON100
RS232 Cable
Converter -> Host P.C.
RS422 Cable
iCON100 -> iCON100
iCON100 -> Converter
Door Lock & ALARM Guide (1Sheet)
Cable Specification
Belden #9409, 18 AWG
2 conductor, unshielded
Belden #9512, 22 AWG
4 conductor, shielded
Belden #9514, 22 AWG
8 conductor, shielded
Belden #9512, 22 AWG
4 conductor, shielded
Belden #9514, 22 AWG
8 conductor, shielded
Belden #9409, 18AWG
2 conductor, unshielded
Belden #9829, 24 AWG
2-twisted pair, shielded
Belden #9830, 24 AWG
3-twisted pair, shielded
2
Quick Installation Guide
Diode (2ea) Resistor2.2k(4ea)
TCP/IP Module(Option)
Maximum
Distance
3m
150m
300m
300m
15m
1,200m