Perkins 1106C Genset Systems Operation Testing And Adjusting page 74

Hide thumbs Also See for 1106C Genset:
Table of Contents

Advertisement

74
Testing and Adjusting Section
Illustration 72
Typical example
1. Install Tooling (A). See illustration 72.
2. Set the pointer of the dial indicator to 0 mm
(0 inch).
3. Check the concentricity at intervals of 45 degrees
around the flywheel housing.
4. Calculate the difference between the lowest
measurement and the highest measurement. This
difference must not be greater than the limit that is
given in Table 14.
Note: Any necessary adjustment must be made on
the flywheel housing. Then, recheck the concentricity.
Alignment of the Flywheel Housing
Note: This check must be made with the flywheel
and the starter removed and the bolts for the flywheel
housing tightened to the correct torque.
g01199468
Illustration 73
Typical example
1. Install Tooling (A). See illustration 73.
2. Set the pointer of the dial indicator to 0 mm
(0 inch).
3. Check the alignment at intervals of 45 degrees
around the flywheel housing.
4. Calculate the difference between the lowest
measurement and the highest measurement. This
difference must not be greater than the limit that is
given in Table 14.
Note: Any necessary adjustment must be made on
the flywheel housing.
Table 14
Limits for Flywheel Housing Runout and Alignment
Bore of the Housing
410 mm (16.14 inch)
448 mm (17.63 inch)
(Total Indicator Reading)
Maximum Limit (Total
Flange
Indicator Reading)
0.25 mm (0.010 inch)
0.28 mm (0.011 inch)