5.7. Connecting I/O Module Interface Cables

This section describes how to connect electrical and optical cables.

5.7.1. Connecting Electrical Port Cables

The 48TX port uses the RJ-45 connector and category-5 twisted pair cable as transmission medium. The 8BT port
uses the RJ-45 connector, shown in Figure 18.
Use the following steps to connect the 48TX port:
1. Plug one end of the straight-through cable into the Ethernet RJ-45 port of the switch.
2. Plug the other end of the straight-through cable into the RJ-45 port of the hub or LAN Switch.
Figure 18 The RJ-45 connector
PIN #8
PIN #1
Note:
Ports on 48TX and 8BT modules support MDI/MDI-X auto-sensing.
Table 27 RJ-45 MDI port pin-outs
Pinout
1
2
3
4
5
6
7
8
Note:
Tx = Send data Rx = Receive data BI = Bi-directional data.
Table 28 RJ-45 MDI-X port pin-outs
Pinout
1
2
3
4
5
6
7
8
10Base-T/100Base-TX
Signal
Function
Tx+
Send data
Tx-
Send data
Rx+
Receive data
Reserved
-
Reserved
-
Rx-
Receive data
Reserved
-
Reserved
-
10Base-T/100Base-TX
Signal
Function
Rx+
Receive data
Rx-
Receive data
Tx+
Send data
Reserved
-
Reserved
-
Tx-
Send data
Reserved
-
Reserved
-
I N S T A L L I N G
1000Base-T
Signal
Function
BIDA+
Send data to direction A
BIDA-
Receive data from direction A
BIDB+
Send data to direction B
BIDC+
Receive data from direction C
BIDC-
Send data to direction C
BIDB-
Receive data from direction B
BIDD+
Send data to direction D
BIDD-
Receive data from direction D
1000Base-T
Signal
Function
BIDB+
Send data to direction B
BIDB-
Receive data from direction B
BIDA+
Send data to direction A
BIDD+
Receive data from direction D
BIDD-
Send data to direction D
BIDA-
Receive data from direction A
BIDC+
Send data to direction C
BIDC-
Receive data from direction C