Changing Settings Using Telnet or RS-232C
Terminals

Changing Settings Using Telnet or RS-232C Terminals

Preparations
Connect the 10BASE-T connector on this unit to the
Ethernet connector on the host computer (PC) with an
Ethernet cable, and make the following preliminary
settings.
For details of installation and connections for this unit,
refer to the supplied Installation Guide.
1
Power on this unit.
2
Power on the PC.
3
Start the terminal software (Tera Term in this
example).
Open the "New connection" dialog box.
4
Check the TCP/IP radio button.
Note
When using the RS-232C connector on this unit
connected to a serial port on the computer, check
the Serial radio button.
5
In the Host box, enter the IP address of this unit,
and then click the OK button.
The default setting of the IP address is
"192.168.1.2".
For details of how to set the IP address, see "To change
the IP address" (page 14).
6
In the setup menu, select "Terminal setup."
A dialog box appears.
7
Confirm the settings, then click the OK button.
Notes
• Increasing the terminal size may cause a
malfunction.
• When using this unit with its RS-232C connector
connected to a computer serial port, set
"Transmit" to "CR." Next, in the setup menu
select "Serial port setup," and check the settings
in the dialog box (see figure below), then click
the OK button.
26