golmar CD-PLUS/4+N Instruction Manual page 7

Protocol converter
Table of Contents

Advertisement

7
P
rogramming the converter.
For the correct operation of this system it must be programmed as indicated in the following
instructions:
Programming methods
Without an IT-4N telephone interface
Connect a T-700 telephone (or equivalent) to the converter's 4+n connection block following the terminal
correspondences (3, 10, 5, 0 and P1).
Master
The converter should be programmed as slave when it is installed in an apartment with a
monitor.
Each apartment must have one master unit only; in case of parallel units configure them as slaves,
whether they are monitors, telephones or converters. The programming of the converter is
complete.
Make a call to check that it has been successfully programmed.
Having completed the programming set the Door panel's programming switch to OFF, or
exit the configuration mode (coded panel) by pressing the C button and disconnect the
T-700 telephone from the converter.
Access the door panel programming mode. If it is a door panel
with pushbuttons set dip switch no. 2 from the EL 500 module to
ON, and if it is a coded panel press the key button followed by the
1
3
1
5
installer Pin (from factory: 1315).
With the door release push button pressed, lift the handset off the
telephone.
To show that the system is ready for programming, the door
panel and handset will emit a tone, and audio communication
can be established. Release the door release push button.
Press the door panel push button that will call this converter, or in
the case of a coded panel, enter the apartment code and press
the button . At this moment both door panel and handset will
emit tones.
With the handset lifted:
To program the converter as master, replace the handset, and to
program it as slave, press the door release push button and finally,
replace the handset.
Slave
PROGRAMMING