5
P
rogramming the converter.
For the correct operation of this system it must be programmed as indicated in the following
instructions:
Programming methods
With an IT-4N telephone interface
With the telephone connected to the output line to telephones of the IT-4N telephone interface.
1
1
2
3
4
5
6
7
8
9
0
#
*
3
6
9
#
3
6
9
#
1
2
3
4
5
6
7
8
9
0
#
*
Master
The converter should be programmed as slave when it is installed in an apartment with a
monitor.
Each apartment must have one master unit only; in case of parallel units configure them as
slaves, whether they are monitors, telephones or converters. The programming of the converter
is complete.
Make a call to check that it has been successfully programmed.
Having completed the programming set the Door panel's programming switch to OFF, or
exit the configuration mode (coded panel) by pressing the C button.
Access the door panel programming mode. If it is a door panel
with pushbuttons set dip switch no. 2 from the EL 500 module to
ON, and if it is a coded panel press the key button followed by the
3
1
5
installer Pin (from factory: 1315).
Enter "##9" code with the telephone buttons to access the
programming mode of the Plus/4N Converter.
To show that the system is ready for programming, the door
panel and handset will emit a tone, audio communication is
established and the green LED on the protocol converter will
blink slowly.
Press the door panel push button that will call this converter, or in
the case of a coded door panel, enter the apartment code and
press the button . At this moment the door panel and handset
will emit tones and the converter's green LED will blink quickly.
With the handset lifted:
1
2
3
If programming the converter as master, replace the handset.
4
5
6
If programming it as slave, press push button 5 and finally, replace
7
8
9
the handset.
0
#
*
Slave
PROGRAMMING

Advertisement