Electrical Box - Daikin ATKM50QRV16 Service Manual

Removal procedure, 5.0/6.0/7.1 kw class

Advertisement

Electrical Box

4. Electrical Box
Warning
Step
1
Remove the screw, and
then the service cover.
2
Remove the screw, and
then the wire fixture.
3
Remove the 4 screws
on the terminal board
and disconnect the
connecting wire.
4
Remove the screw and
release the earth/
ground wire.
5
Pull out the indoor heat
exchanger thermistor.
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Terminal board
Earth/ground wire
Service
cover
(R20146)
Wire fixture
Connecting
wire
(R20147)
Be careful not to lose the clip
of the thermistor.
Clip
Indoor heat
exchanger
thermistor
(R23481)
Si041403EB
Points
(R11268)