Download Print this page

Daikin ATKM50QRV16 Service Manual page 11

Removal procedure, 5.0/6.0/7.1 kw class

Advertisement

Si041403EB
Step
4
Release the harness
from the 4 hooks.
5
Disconnect the
connector [S27].
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Remove the
INTELLIGENT EYE
sealing material.
2
Disconnect the
connector [S36].
3
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
3. Remove the control PCB.
1
Unfasten the hook from
the right side of the
electrical box.
Removal Procedure
Procedure
Hook
Hook
[S36]
Hook
[S27]: control PCB
[S27]
(R20156)
[S36]: control PCB
Some models do not have
INTELLIGENT EYE sensor.
When reassembling, put the
INTELLIGENT
harness for [S27] and [S36]
EYE sealing
on the 4 hooks.
material
Hook
(R23575)
INTELLIGENT
EYE sensor
PCB
Hook
(R20158)
Hook
(R20159)
PCBs
Points
Hook
(R22590)
9