Download Print this page

Daikin ATKM50QRV16 Service Manual page 9

Removal procedure, 5.0/6.0/7.1 kw class

Advertisement

Si041403EB
Step
6
Disconnect the 4
connectors.
7
Release the harnesses
from the 4 hooks.
8
Remove the screw of
the electrical box.
9
Lift up and remove the
electrical box from the
bottom frame.
Removal Procedure
Procedure
Hook
Electrical box
[S1]: fan motor
[S6]: swing motor (horizontal
blade)
[S7]: fan motor (Hall IC)
[S8]: swing motor (vertical
[S1]
blade)
[S6]
DC fan motor models do not
[S7]
have harness for [S7].
[S8]
(R20149)
Hook
(R20150)
(R20151)
When reassembling, fasten
the 2 hooks at the back of
the electrical box.
Hook
Bottom frame
(R20152)
Electrical Box
Points
7

Hide quick links: