INSTALLATION INSTRUCTIONS
__________________________
After you have followed all instructions in PART ONE you are ready to install the heater assembly.
How do I configure my wattage?
STEP 1
Multi-Watt Element Wiring Configuration:
STEP 1
STEP 1
The multi-watt heaters listed below are factory set for the highest possible wattage. If you would like to keep the wattage at the highest
setting, proceed to Step 2. If you would like to reduce your heater's wattage from the factory setting, refer to the table below that corre-
sponds to your heater model. Once you are finished, proceed to Step 2.
NEVER DISCONNECT THE BLUE CONNECTOR FROM TERMINAL "D"
CM192/CM198
No change
1900
Disconnect and cut wire with Blue Connector at
Terminal B. Cap loose end with wire connector
1500
or wrap with electrical tape. Move Yellow
Connector from Terminal A to Terminal B.
Disconnect and cut wire with Blue Connector at
Terminal B. Cap loose end with wire connector
1100
or wrap with electrical tape. Move Yellow
Connector from Terminal C to Terminal B.
Cut jumper wire between terminals A and C.
Cap loose ends with wire connector or wrap
700
with electrical tape. Remove connectors at
Terminals B and C. Move Yellow Connector
from Terminal A to Terminal B.
Cut jumper wire between terminals A and C.
Remove connectors at Terminals B and C.
400
Cap loose ends with wire connector or wrap
with electrical tape.
How do I insert the heater assembly into the wall can?
Install Heater Assembly
STEP 2
Turn heater assembly upside down (Element down with motor
facing you). Connect the supply wires to the heater wires with
connectors (See Figure 7). Now rotate the heater so the element
and the fan are facing you.
For VERTICALLY MOUNTED units the element should be at the
top. Insert the bottom edge of the heater assembly into the half
round slots (tabs) in the bottom lip of the wall can (See Figure 8a).
[IMPORTANT: Push wires into bottom of wall can during insertion. Be sure that supply wires are not caught between motor and wall
can.] Attach assembly at top with screw provided.
For HORIZONTALLY MOUNTED units the element should be to the left. Insert the right edge of the heater assembly into the half round
slots (tabs) on the right side of the wall can (See Figure 8b). [IMPORTANT: Push wires into right side of wall can during insertion. Be
sure that supply wires are not caught between motor and wall can.] Attach assembly at left with screw provided.
STEP 3
Install Grill
Secure grill with the screws provided. If you have a built-in thermostat model, slide thermo stat knob onto
shaft. Turn power on at the electrical panel board.
Warranty is void if any material is sprayed on the element or blower. Use a paint mask to cover any exposed
areas of the heater if walls are to be textured or painted.
GRILL
Page 4
Figure 4a
Vertical
Mounting
B
WIRE CONFIGURATION
C
D
FACTORY SET
AT 1500 WATTS
NEVER DISCONNECT THE BLUE CONNECTOR FROM TERMINAL "D"
Figure 8a
TAB
Figure 8b
Figure 4b
Horizontal
Mounting
__________________________
Part Two
NEVER DISCONNECT THE BLUE CONNECTOR FROM TERMINAL "D"
CM152/CM158
MODELS
Figure 5a
CM192
CM198
1900
Watt
Config-
uration
Shown
(table
above
GRILL
(continued)
WIRE CONFIGURATION
No change
1500
Disconnect and cut wire with Blue
Connector at Terminal B. Cap loose
800
end with wire connector or wrap
with electrical tape.
Disconnect and cut wire with Blue
Connector at Terminal B. Cap loose
end with wire connector or wrap
700
with electrical tape. Move yellow
connector from Terminal C to
Terminal B
For
CM192/CM198
B
A
and
C
D
left)
FACTORY SET
Figure 6a
AT 1900 WATTS
NEVER DISCONNECT THE BLUE CONNECTOR FROM TERMINAL "D"
TAB
Figure 7
Figure 5b
For
WIRE CONFIGURATION
MODELS
B
No change
1900
CM152
Disconnect and cut wire with Blue Connector a
and
Terminal B. Cap loose end with wire connecto
1500
CM158
or wrap with electrical tape. Move Yellow
C
Connector from Terminal A to Terminal B.
1500
Disconnect and cut wire with Blue Connector
Watt
Terminal B. Cap loose end with wire connect
1100
or wrap with electrical tape. Move Yellow
Config-
Connector from Terminal C to Terminal B.
uration
Cut jumper wire between terminals A and C.
Shown
Cap loose ends with wire connector or wrap
700
with electrical tape. Remove connectors at
(table
D
Terminals B and C. Move Yellow Connector
above)
from Terminal A to Terminal B.
Cut jumper wire between terminals A and C.
FACTORY SET
Remove connectors at Terminals B and C.
Figure 6b
400
Cap loose ends with wire connector or wrap
AT 1500 WATTS
with electrical tape.
NEVER DISCONNECT THE BLUE CON
Supply Wires
Heater
Wires
Motor
Top
CM152/CM
1500
800
700

Advertisement

loading

This manual is also suitable for:

Cm152Cm192Cm152tCm192tCm158Cm198 ... Show all