Emx Irb-Mon Single Gate - Max 1500 PRO Installation Manual

Slide gate operators
Table of Contents

Advertisement

emx irb-mon
Transmitter
(TX)
CLOSING direction Thru-Beam
To Matrix III
12VDC OUT Input
Transmitter (TX)
TX
Green
POWER INPUT
LED
TRANSMITTER
BOARD (TX)
IMPORTANT:
by Matrix III or they will NOT be MONITORED.
OPEN ONLY
P
P
P
P
PHOTO CLS
OPEN/CLS
12VDC OUT
OPEN ONLY
CLS ONLY
OPEN/CLS
12VDC OUT
Photocell (Thru-Beam) CLOSING Direction
Single Gate Operator
Receiver
To PHOTO CLS NC
(RX)
and 12VDC OUT Input
Gate Closed
Single
Operator
Installation Steps:
1. Set DIP-switches on receiver.
2. Install jumper on receiver.
3. Wire Matrix III 12VDC OUT
power to receiver.
4. Wire PHOTO CLS NC
to receiver photocell NC.
Wire Matrix III GND to
receiver photocell COM.
5. Wire 12V Matrix III
power to transmitter.
6. Align photocells.
7. Adjust sensitivity on receiver.
Photocells MUST be powered
NC
PHOTO CLS NC -
NC
NC
GND
GND -
Common
10K
10K
10K
GND
T X
R X
Sensitivity Adjustment:
If the photocell does not
respond to an obstruction,
lower the sensitivity by
turning adjustment
counter-clockwise.
DIP-switches:
1, 2, 3 are OFF.
Switch 4 is ON
If trouble occurs, try
turning switch 4 OFF.
NOTE: Power must be
cycled when switches
are changed.
Jumper MUST be on Com-NC.
N O
C o
12VDC OUT
Polarity does NOT matter
Normally Closed
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a
24
IMPORTANT:
Photocells MUST be
in alignment or fault will occur.
Green LED will remain ON receiver
when in proper alignment.
Receiver (RX)
RX
NO
COM
NC
NC
COM NO
POWER
INPUT
JUMPER
m N
RECEIVER
C
BOARD (RX)
NOTE: To meet the UL 325 2018 standard, Type B1
Non-Contact sensor entrapment protection device
MUST be MONITORED by the gate operator.
Green
LED
SENSITIVITY
EARTH
GND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2200 proF18 pro

Table of Contents