Festool OF 1010 EQ Instruction Manual page 6

Router
Hide thumbs Also See for OF 1010 EQ:
Table of Contents

Advertisement

6
1.1
Locking button / Bouton de blocage / Botón de bloqueo
1.2
On/Off switch / Interrupteur marche/arrêt / Interruptor
de conexión/desconexión
1.3
Depth adjustment / Réglage en profondeur / Ajuste de
la profundidad de fresado
1.4
Scale / Graduation / Escala
1.5
Extractor connection piece / Manchon d’aspiration /
Boquilla de aspiración
1.6
Pivoted turret stop / Butée tournante / Tope de revólver
1.7
Collet nut / L’écrou de la pince de serrage / Tuerca de la
pinza
1.8
Spindle stop / Dispositif d’arrêt de l’axe / Dispositivo de
bloqueo del husillo
1.9
A d d i t i o n a l h a n d l e / Po i g n é e s u p p l é m e n t a i r e /
Empuñadura adicional
1.10 Speed controller / Régulateur de vitesse de rotation /
Regulador del número de revoluciones
1.B
Connecting and disconnecting power cable / connexion
et déconnexion du câble de raccordement au secteur /
conectar y sacar el cable de conexión a la red
Downloaded from
www.Manualslib.com
manuals search engine
Various dust created by power sanding, sawing,
grinding, drilling and other construction activities contains
chemicals known (to the State of California) to cause cancer,
birth defects or other reproductive harm. Some examples
of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and other masonry
products, and
• arsenic and chromium from chemically-treated lumber.
The risk from these exposures varies, depending on how
often you do this type of work.
To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment,
such as dust masks that are specially designed to filter out
microscopic particles.
Technical data
Power input
Speed of drive shaft
Quick height adjustment
Fine height adjustment
Drive shaft connection of the spindle
Weight
Safety
acc. UL 745, CSA C22.2 No. 745
1
Symbols
V
volts
A
amperes
Hz
hertz
W
watt
~
alternating current
n
no load speed
0
Class II Construction
rpm
revolutions or reciprocation per minute
2
Functional description
2.1 Intended use
The routers are designed for routing wood, plastics and similar
materials. Aluminium and plasterboard can also be processed
with corresponding cutters such as are listed in the
Festoolcatalogues. The user is liable for damages and injuries
due to incorrect usage.
2.2 Electrical connection
The network voltage must conform to the voltage indicated
on the rating plate. A 16 A safety fuse (for 120 V) or a
corresponding protective circuit-breaker is required.
Under no circumstances should the electrical tool be used
when the power cable is damaged. A damaged cable must be
replaced immediately by an authorised Customer Service
Centre. Do not try to repair the damaged cable yourself. The
use of damaged power cables can lead to an electric shock.
See Fig. 1B for connection and disconnection of the power
cable.
Always switch the machine off before
connecting or disconnecting the power cable!
2.3 Extension cable
If an extension cable is required, it must have a sufficient
cross-section so as to prevent an excessive drop in voltage or
overheating. An excessive drop in voltage reduces the output
and can lead to failure of the motor. The table beside shows
you the correct cable diameter as a function of the cable length
for the router OF 1010 EQ. Use only U.L. and CSA listed
extension cables. Never use two extension cables together.
Instead, use one long one.
OF 1010 EQ
1010 W
10 000 - 23 000 rpm
55 mm
8 mm
M 14 x 1.5
2.7 kg / 6.0 lbs

Advertisement

Table of Contents
loading

Table of Contents