Error Mode Display
Power Heater Check Blue LED
(No display. No Operation.)
Power
Heater
Check Blue LED
or
(Tamper prevention timer)
Power
Heater Check Blue LED
(Motor over-revolution, out-of-order errors)
Power
Heater Check Blue LED
(Motor start error, motor lock)
Power
Heater Check Blue LED
(Over-current error)
Power Heater Check Blue LED
(Detection of over-voltage,
under-voltage)
Cause
When 120 V is supplied, check the following points.
Blown current
Check if the current fuses (FUSE1, 2, 3) on the control circuit
board are blown or not.
fuse
If any current fuse is blown, replace the control circuit board.
If any voltage higher than 120V is applied by an error during
the power supply work, FUSE3 (5A) may be blown and ZNR1
may be destroyed.
Blown motor
1Check if the relay connector of motor temperature fuse is
temperature fuse
disconnected. (In the terminal block box)
2Check if TAB5 and TAB6 connectors are disconnected.
3To see if the motor temperature fuse is blown, measure the
resistance between motor lead wires "Blue-Blue".
Disconnected indicator
Check if CN6 or CN11 is disconnected.
circuit board lead wire
(CN11 is on the indicator circuit board.)
Defective control
If no error is found after checking the above, replace the
circuit
control circuit board.
Leftover object
Check for any object left over and shielding the sensor in the
drying area.
Dirty sensor
Dirty window may shield incoming light. Make clean the
window
sensor window.
Defective motor
Replace the motor.
Defective control
If no error is found after checking the above, replace the
circuit
control circuit.
Defective motor
Check if the motor is locked or does it turn smoothly by hand.
Defective control
If no error is found after checking the above, replace the
circuit
control circuit.
Connection error
Check if TAB5, 6, 7, 8 or 9 is connected incorrectly to the
control circuit.
Motor overload
Check for causes of motor overload. (Too much higher power
supply voltage, any object disturbing the motor revolution,
etc.)
Defective control
If no error is found after checking the above, replace the
circuit
control circuit.
Application of
Check if correct power supply voltage is applied.
over-voltage
• Error will occur if the power supply voltage is at about AC162V or over.
Application of
Check if correct power supply voltage is applied.
under-voltage
• Error will occur if the power supply voltage is at about AC60V or under.
Defective control
If no error is found after checking the above, replace the
circuit
control circuit.
— 20 —
Check Method and Remedy
Blue
Blue
Red
Black
White
Normal value: 0 Ω
Abnormal value:
side
Tester
side
Ω