(4) Control of the heater temperature
1 Room thermostat detects the room temperature while the heater thermostat monitors the heater
temperature.
2 The room thermostat temperature determines the heater control temperature. (The colder the room
temperature, the heater control temperature becomes higher, and the hot air temperature is maintained at
about 35°C.)
3 Heater turns ON/OFF depending on the heater control temperature, but it does not turn ON in the following
occasions.
• When the heater switch is turned "OFF" (Heater lamp is extinguished.)
• When the jet towel is operating
• When the room thermostat detection temperature is 35°C or higher
(5) Extinguishing of the illumination lamp
1 If the jumper wire (JA) on the indicator circuit board (JT-24S-A) is cut off, the illumination lamp extinguishes.
2 Before cutting off the jumper wire, make sure to turn the power switch "OFF" and wait for 40 seconds
minimum.
(6) Test mode (Error display mode)
1 Content ................. Display the latest error occurred.
2 Setting method ....... In the condition that a resistor of 4.7kΩ is connected between pins 1 and 2 of CN8 on
3 Resetting method ... Turn "OFF" the power switch. After waiting for more than 40 seconds, remove the
When no error is retained in the memory, the power lamp flickers quickly.
There is no other indication than the above. (Operation is inhibited.)
the main circuit board, turn "ON" the power switch.
above resistor.
— 18 —