CAUTION
!
ELECTRICAL OPERATION HAZARD
Failure to follow this caution may result in equipment damage
or improper operation.
Improper wiring of the ABCD connector will cause the
Infinity System to operate improperly. Check to make sure all
wiring is correct before proceeding with installation or turning
on power.
9. Push any excess wire into the wall. Seal hole in wall to pre-
vent any air leaks. Leaks can affect operation.
10. Attach Infinity Control to the mounting plastic by lining up
the plastic guides on the back of the control with the open-
ing on the mounting plastic and push on.
11. Perform installation of all other system equipment (i.e.
dampers, humidifier, ventilator, UV lights, etc.).
12. Turn on power to equipment.
See wiring diagram, Fig. 11, which includes an indoor
communicating furnace or FE fan coil, with a communicating
outdoor unit. No additional OAT (outdoor air temperature) sensor
is required because the Infinity Control will use the temperature
sensor inside the outdoor unit.
See wiring diagram, Fig. 12, for connecting an indoor
communicating furnace or FE fan coil with a 1- -stage air
conditioning unit (non- -communicating outdoor). An Outdoor Air
Temperature (OAT) sensor may be installed (but is not required) at
the indoor furnace or fan coil OAT terminals. When OAT sensor is
applied, the Infinity System will provide enhanced system features
and benefits.
See wiring diagram, Fig. 13, for connecting an FE fan coil with a
1- -stage heat pump (non- -communicating outdoor unit). When
OAT is applied, the Infinity System will provide enhanced system
features and benefits.
In a hybrid heat installation with a non- -communicating heat pump,
an OAT sensor must be installed, or the heat pump with not run.
NOTE: For other applications not listed, refer to the Network
Interface Module (NIM) Installation Instructions.
Humidifier Connection
A 24VAC bypass or fan powered humidifier may be installed.
NOTE: Do Not Use a traditional humidistat to control humidifier
operation. If a humidifier is installed, let the Infinity Control
operate humidifier.
Bypass Humidifiers
A bypass humidifier should be wired directly to the furnace or fan
coil HUM and 24VAC COM terminals. The Infinity Control will
automatically energize the HUM output during a call for
humidification.
Fan Powered Humidifiers
Most fan powered humidifiers produce internal 24VAC in order to
energize upon a switch or contact closure. For this application, a
24VAC N.O. Isolation Relay (DPST) MUST be used to prevent
mixing the internal humidifier power with the indoor equipment
transformer. Applying 24VAC isolation relay coil to furnace or fan
coil HUM and COM terminals will allow the Infinity Control to
automatically energize the HUM output during a call for
humidification. The N.O. relay contacts will be used to energize the
humidifier. See fan powered humidifier installation instructions for
more details.
CAUTION
!
EQUIPMENT HAZARD
Failure to follow this caution may result in equipment damage.
Do not apply 24VAC fan powered humidifier (with internal
power supply) direct to indoor unit HUM and COM terminals.

INITIAL POWER- -UP

NOTE: Refer to Functional Overview (see Fig. 15) to become
familiar with key function buttons such as "System On/Off,"
"Fan," "Left- -Side" and "Right- -Side" buttons, etc. These function
buttons will be used frequently during setup.
Humidity/OAT
Button
Left-Side
Button
Time (+/-)
Button
Hold
Button
HOLD
SCROLL
SCHEDULE
VACATION
Schedule & Vacation
Program Buttons
PROGRAM
Up/Down
Scroll Buttons
Schedule
Vacation
to program
to start/end
temperature
vacation
schedule
Scroll
up & down
Fig. 15 - - Functional Overview
Power Up Sequence
This section addresses initial power up (or commissioning) of a
new Infinity Control. The User Interface will communicate and
identify all Infinity components in the system. The following is a
typical example for a communicating Variable- -Speed Furnace /
Fan Coil with a 2- -stage Air Conditioner / Heat Pump (including
Hybrid Heat).
The User Interface display will light up and indicate that it is now
"ESTABLISHING COMMUNICATIONS WITH EQUIPMENT
PLEASE WAIT". The User Interface will automatically continue
by
"SEARCHING
FOR
"SEARCHING FOR OUTDOOR EQUIPMENT" (see Fig. 16).
Once the indoor and outdoor equipment has been found, the
Installer will be asked to select Accessories. Packaged Products
will be automatically identified and the Installer will be asked to
select Accessories. Proceed to Selecting Accessories.
INDOOR UNIT
ESTABLISHING
COMMUNICATIONS
SEARCHING FOR
INDOOR EQUIPMENT
WITH EQUIPMENT
PLEASE WAIT
WORKING
SOFTWARE
VERSION
Fig. 16 - - Power Up Sequence
5
Fan Button
Display Screen
(LCD)
Right-Side
Button
HEAT
Heat Button
Cool Button
COOL
Temperature
(+/-) Button
System
On/Off Button
BASIC
ADVANCED
Basic & Advanced
Setup Buttons
SETUPS
Basic
Advanced
Flip Down
to set time,
for all other
Door
humidity
settings
A03194
EQUIPMENT",
followed
OUTDOOR UNIT
SEARCHING FOR
OUTDOOR EQUIPMENT
WORKING
A03195
by