Drum Mounted System - Graco 24H689 Instructions Manual

Ld oil or grease system packages
Table of Contents

Advertisement

LD Pump Oil and Grease Drum Mounted System
LD Pump Oil and Grease

Drum Mounted System

For oil or grease drum LD pump
installation. For dispensing lubricants only.
For professional use only.
Not for use in explosive atmospheres.
The Drum Mount Packages include a universal pump
and dispense valve. See page 16 for a complete list of
packages and associated components.
Grease models require a follow plate for pumping fluid
from the drum. See page 17 for follow plate installation
instructions.
16
Oil Models
Grease Models
Pump Installation
Reference numbers used in the following instructions
refer to Parts, page 30.
This installation procedure can be used for both Oil and
Grease applications. When pumping grease, a follow
plate is also required. See Installing Follow Plate
instructions, page 17.
1. Thread pump bung adapter (1a) into hole in drum
cover (16) and hand tighten securely (F
2. Insert pump (1) into bung adapter (1a) and drum.
3. Secure the pump in place by tightening the gasket
screws (1b) (F
. 23).
IG
4. Ground pump. See Grounding Instructions, page 4.
2a
2c
1b
F
. 23
IG
. 23).
IG
1
1a
3A1335K

Advertisement

Table of Contents
loading

Table of Contents