Stainless steel 3:1 pump, for use in ecoquip vapor abrasive blast equipment, use only with water, or water with additives to inhibit corrosion or mold, for professional use only
Displacement pump for ultra max 695, series a ultimate mx 695, series a ultra 395/495/595 ultimate nova 395 ultimate super nova 495/595 st max 395/495/595 performance max 395/495/595 ultra max 695, series b ultra 695, series a ultimate mx 695, series b ul (14 pages)
Page 1
For professional use only. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Model 24V672 300 psi (2.06 MPa, 20.6 bar) Maximum Fluid Working Pressure 100 psi (0.68 MPa, 6.8 bar) Maximum Air Working Pressure...
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Component Identification Component Identification . 1. Component Identification Ref. Description Ref. Description Displacement Rod Ground Screw Tie Rod Enclosed Wet Cup Coupling Nut Wet Cup Fill Port Tie Rod Nut Fluid Outlet Air Motor Fluid Inlet Sight Glass Lower Cylinder Outlet Housing 333397A...
Pressure Relief Procedure Follow the Pressure Relief Procedure whenever you see this symbol. Before starting, fill wet cup fill port (C) 1/2 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See F . 3. This equipment stays pressurized until pressure is manually relieved.
Wet Cup Maintenance and what kind of maintenance is needed, and then determine a regular schedule for checking your system. Fill the Wet Cup half full with Graco TSL. Maintain level daily. 333397A...
Troubleshooting Troubleshooting NOTE: Perform Pressure Relief Procedure (page 5) before checking or servicing the equipment. NOTE: Check all possible problems and causes before disassembling the pump. Pump Problem Cause Solution Pump output is low on both strokes. Air supply lines are restricted. Clear any obstructions from the air lines.
Troubleshooting Air Motor Problem Cause Solution Air motor will not run. Damaged air valve (214). Replace or service the air valve (214). See F . 13, page 20. Damaged pilot valve (213). Replace the pilot valves (213). See F . 13, page 20. Air is continuously exhausting Damaged u-cups (207).
5. See F . 11, page 17. Unscrew the tie rod nuts (4) • Always use Genuine Graco Parts and Accessories, from the tie rods (3). Unscrew coupler and remove available from your Graco distributor. Accessories coupler collars. Carefully pull the displacement must be adequately sized and pressure rated for pump (2) off of the air motor.
(110). Take note which set of holes it is in, then during repair. Torque the enclosed wet cup (B) to 60 remove the ball (102). ft-lb (81 N•m). Fill the wet cup fill port (C) with Graco TSL. 6. Place the flats of the piston mounting stud (128) in a vise, and unscrew the piston stud (114).
Pump Repair Reassemble the Displacement 4. Screw the piston stud (114) onto the piston mount- ing stud (128). Torque to 50–70 ft-lb (68–95 N•m). Pump Install the piston ball (102*) on the piston seat. Slide the ball stop pin (110*) into the desired set of holes, 1.
Pump Repair Pump Diagram Torque to 60 ft-lb (4.1 N•m) Lips of v-packings must be face up Lubricate See Detail A Apply lubricant See Detail B Lips of v-packings must be face down Detail A: Throat Packings Detail B: Piston Packings ti23797a 333397A...
Air Motor Repair Air Motor Repair 3. Attach the tie rod nuts (4) and torque to 15-20 ft-lb (20-27 N•m). 4. Hold the flats of the air motor piston rod with a wrench. Use another wrench to tighten the coupling Disconnect the Air Motor nut (9).
Page 14
Air Motor Repair Replace Seals or Rebuild Air Valve 2. See F . 7. Lubricate the u-cups (309†◆) and install on the piston (306◆) with the lips facing toward the Air Valve Seal Kits are available. See page 25 to order center of the piston.
Air Motor Repair Replace Pilot Valves Repair Air Motor 1. Stop the pump at the middle of its stroke. Perform Disassemble the Air Motor the Pressure Relieve Procedure, page 5. 2. Disconnect the air line to the motor. 1. For motors with DataTrak: Remove the screw to disconnect the reed switch from the air valve.
Page 16
Air Motor Repair Reassemble the Air Motor 8. See F . 10. Carefully place the bottom cover (201) on the cylinder (205). Slide the rod through the NOTE: For easier reassembly, start with the top cover bearing. The manifold surfaces of the top and bot- (210) turned over on the workbench and assemble the tom covers must align.
Parts Parts Pump Parts Pump Parts List Ref. Part Description Qty. M02LN0 MOTOR, air, 2.5 in. 24V671 LOWER, displacement, sst 17B185 ROD, tie (Pack of 3) 104541 NUT, locl 102228 COVER, oil hole 15M758 NUT, coupler, lower 184132 COLLAR, coupling See Air Motor Kits and Accessories, page 25.
Parts Air Valve Parts . 14: Air Valve Parts Air Valve Parts List Ref. Part Description Qty. Ref. Part Description Qty. 301 † ◆ 310◆ ROLLER, detent, small O-RING, 018 buna ✖ HOUSING, air valve, small, npt †✖ SCREW, M3, thread forming ✖...
Parts Air Valve Parts List Air valve parts are not sold individually. The table below shows possible kit options for each part. See page 25 to order the correct kit(s), or full replacement air valves, for your motor. Air Valve Air Valve Air Valve Ref.
Mounting Hole Diagram Mounting Hole Diagram M02xxx (2.5 in.) 3 in. (76 mm) Two M8 mounting holes ti12734a Three 3/8-24 tie rod holes M8 X 1.25 3-1/4 in. (83 mm) bolt circle 2.2 in. (56 mm) ti12733a 2.5 in. (64 mm) 333397A...
Air Motor Kits and Accessories Air Motor Kits and Accessories Kit Description Kit Number ✖ Complete Air Valve Replacement Kit – Standard 24A351 * Air Motor Seal Kit 24A539 ◆ Air Valve Repair Kit 24A537 † Air Valve Seal Kit 24A535 ✠...
Dimensions Dimensions Pump 5.5 in (14 cm) 4.2 in (11 cm) 26.5 in (67 cm) 6.2 in (16 cm) Air Motor 6.2 in. (157 mm) 6.8 in. 4.2 in. 5.1 in. (173 mm) (107 mm) (130 mm) 9.2 in. (234 mm) 333397A...
Technical Data Technical Data Stainless Steel 3:1 Pump - 24V672 Metric Maximum fluid working pressure 300 psi 2.06 MPa, 20.6 bar Maximum air inlet pressure 100 psi 0.68 MPa, 6.89 bar Minimum air inlet pressure 15 psi .0103 MPa, 1.03 bar Maximum ambient air temperature 49°...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.