Factory Defaults - KAEL Muhendislik Elektronik VARkombi-12-PC-TFT-OG Manual

Connection type selective, 12 step, reactive power control relay, industrial facilities, markets, oil stations, schools, workshops, hotels
Table of Contents

Advertisement

Factory Defaults

1 8
This is the section which is used to restore factory default values to the
device.
Factory Default Values :
Target TanΦ(cosΦ)
Switch on (Decharge) Time
Switch off Time
Switch min. Time
Inductive Penalty Limit (%)
Capacitive Penalty Limit (%)
Current Transformer (Primary) Value
Number of steps
ΔT on Transition(Delay) Time
ΔT off Transition(Delay) Time
Continuous Current Flow Direction Detection
Fast Step Mode
Connection Type
Continuous Step Power Detection
Constant Step Function
Step Synch. Time Sharing
Phase Alarms – Over Voltage
Phase Alarms – Under Voltage
Phase Alarms – Over Current
Phase Alarms – Over Compensation
Phase Alarms – Under Compensation
Phase Alarms – No Phase
Phase Alarms – THD on Voltage
Phase Alarms – HD on Voltage
Phase Alarms – THD on Current
Phase Alarms – HD on Current
General Alarms – 1. connector failure
General Alarms – 2. connector failure
General Alarms – Total Over Compensation
General Alarms – Total Under Compensation
General Alarms – System Failure
General Alarms – Over Temperature
General Alarms – Voltage Connection Failure
General Alarms – Step Change
General Alarms – Step Zero
General Alarms – Modbus Security Failure
Alarm Setting Values – Over Voltage
Alarm Setting Values – Under Voltage
Alarm Setting Values – Over Temperature
Alarm Setting Values – THD Voltage
Alarm Setting Values – HD Voltage
Alarm Setting Values – THD Current
Alarm Setting Values – HD Current
Fan Settings – Fan Temperature Value
Fan Settings – Fan Output
Level Protection Function–Temperature Protection : disable
Level Protection Function – Voltage Protection
Level Protection Function – Harmonic Protection : disable
Password Procedure – Password Settings
Password Procedure – Default Password
MODBUS RTU Setup – Data Write Protection
MODBUS RTU Setup – Data Read Protection
MODBUS RTU Setup – Data Write Password
MODBUS RTU Setup – Data Read Password
MODBUS Port Setup – Baud Rate
MODBUS Port Setup – Stop Bits
MODBUS Port Setup – Parity
MODBUS Port Setup – Device No
PS 1 : User password is defined as "0000" at first. However, after password is changed, password will not change even if
returned to the factory settings. The last password that the user entered is valid.
PS 2 : It is different than the user password of the device. However it can be entered into the device manually, it can not
be changed by remote access. In case of restoring factory settings, "0000" is appointed to modbus password.
PS 3 : In case of restoring factory settings, the current directions, capacitor powers, energies and counter indexes that
the device internalized before, are reset.
In case of restoring factory settings, all the changes that the user made, except password, will be cancelled.
: % 0
: 20 sec
: 15 sec
: 10 sec
: % 15
: % 10
: 5 / 5 A
: 12
: 0 sec
: 0 sec
: enable
: enable
: WYE
: enable
: disable
: disable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: enable
: 250V
: 180V
: 70 °C
: % 10
: % 10
: % 30
: % 30
: 50 °C
: disable
: disable
: enable
: 0000 (refer to PS1)
: disable
: disable
: 0000 (refer to PS2)
: 0000 (refer to PS2)
: 9600
: 1
: No
: 1
1
2 3
4
5 6
7
8 9
10
11
12
30
SETUP
1 8
Power
Energy
Counter Index
Settings
Factory Defaults
Select
Exit
1
2 3
4
5 6
7
8 9
10
11
12
30
Device
will return
factory settings
Yes
Cancel
1
2 3
4
5 6
7
8 9
10
11
12
30
Install the device
to the Factory
Device
Settings
will reset ?
Yes
Cancel
1
2 3 4 5 6 7 8 9 10 11 12
30
Factory defaults
of the device are loading
27

Advertisement

Table of Contents
loading

Table of Contents