Description
The Crestron
FT2A-PWR-UN-1-C14 module provides one universal ac power outlet for
®
use with the FT2 series of FlipTop™ cable managment devices. The module may be used
to power laptops and other ac-powered devices at the table.
The FT2A-PWR-UN-1-C14 module is suitable for use in the United States, Canada,
Mexico, Europe, United Kingdom, Japan, Korea, Singapore, Saudi Arabia, Australia, New
Zealand, China, and other countries or regions where Plug Types B, F, G, or I power
outlets are used.
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
Overview
The FT2A-PWR-UN-1-C14 has the following speci cations:
• Each FT2A-PWR-UN-1-C14 module provides one universal ac power outlet that is
rated for 10 A (total) at 100–240 Vac, 50/60 Hz.
• An IEC C-14 socket is provided on the bottom of each module, which is used to
connect the module to a power source via an IEC power cord rated for 10 A or better
(not included).
• One blank plate is provided with the FT2A-PWR-UN-1-C14 module for use with
low-pro le power cords. Refer to the note below.
FT2A-PWR-UN-1-C14
module
NOTE: If low-pro le power cords are expected to be used with the
FT2A-PWR-UN-1-C14 module, ensure that the provided blank plate is installed to the
right of the module.
Low-pro le power
cord must clear top
of FT2 series bezel
Each module is 1.97 x 1.97 in (50 x 50 mm) and occupies two empty module spaces in an
FT2 series assembly.
Blank plate
Installation
Use the following procedure to install the FT2A-PWR-UN-1-C14 module into an FT2 series
assembly.
If the FT2A-PWR-UN-1-C14 module is being installed as part of a new FT2 series FlipTop
device installation, proceed to step 3 below.
Install the FT2A-PWR-UN-1-C14 Module
1. Remove the magnetic bezel from the FT2 series assembly by grasping the inside of
the bezel and pulling it up and away rmly from the assembly until the magnetic hold
is broken.
2. Unscrew and remove the two locking bars that secure the module row required for
installation.
For example, if installing the FT2A-PWR-UN-1-C14 module in the front row of an
FT2-700 series FlipTop device, remove the front and center locking bars.
Locking bar
(center)
Locking bar
(front)
3. Connect an IEC power cord (rated for 10 A or better) to the IEC C-14 socket on the
bottom of the FT2A-PWR-UN-1-C14 module.
FT2A-PWR-UN-1-C14
module (bottom view)
IEC C-14
socket
Locking bar
(rear)