General Information

Literature History
CVGF-SVX03B-EN
(March 2016)
This is a new manual.
About this manual
This manual describes proper installation
of Model CVGF, 50 Hz and 60 Hz chillers
with the AdaptiView Controls platform.
See Figures 2 and 3 for an illustration of
a CVGF Centrifugal Chiller with the Adap-
tiView Unit Control Panel. These chillers
are equipped with microcomputer-based
control systems. A careful review of this
information along with the submittal
package provided for the unit will assure
that the chiller is correctly installed.
Operation and maintenance information
for models CVGF are covered in this man-
ual. This includes both 50 and 60 Hz. CVGF
centrifugal chillers equipped with the Trac-
er AdaptiVew Chiller Controller system.
A typical product description block is
shown in the Manual.
Carefully review this information and fol-
low the instructions given to successfully
install operate and maintain a CVGF unit.
If mechanical problems do occur, contact
a qualified service organization to ensure
proper diagnosis and repair of the unit.
Unit Nameplate
When the unit arrives, compare all name-
plate data with order, submittal and ship-
ping information. A typical unit nameplate
is shown in Figure 1.
The unit nameplate is located on the left
side of the unit control panel.
Note: Trane starters are identified by a
separate model number found on the
starter.
4
Figure 1. Typical unit nameplate
MODEL: CVGF500
MODEL NO:
CVGF0500RA0U33809405C1B5C1C23A1A201E3AA0
SERIAL NO:
ELECTRICAL CHARACTERISTICS:
RATED VOLTAGE:
NAMEPLATE NMKW:
VOLTAGE UTILIZATION RANGE:
MINIMUM CIRCUIT AMPACITY:
MAXIMUM FUSE:
MAXIMUM CIRCUIT BREAKER
MAXIMUM OVERLOAD TRIP: 617 AMPS
COMPRESSOR MOTOR
OIL PUMP MOTOR
380
OIL TANK HEATER
115
CONTROL CIRCUIT
115
WHEN MOTOR CONTROLLER PROVIDED BY OTHERS
TRANE ENGINEERING SPEC. S6516-0360 APPLIES
GENERAL CHARACTERISTICS:
REFRIGERANT SYSTEM
TO BE FIELD CHARGED
WITH 340 KG OF R-134A WITH KG OF R-134A
MAXIMUM REFRIGERANT WORKING PRESSURE
HI SIDE 15.2 BAR
FACTORY TEST PRESSURE
HI SIDE 16.7 BAR
FIELD LEAK TEST PRESSURE
TESTED AT
LEAK TEST AND CHARGING SPECIFICATION ARE SUPPLIED
IN CONTROL PANEL (SERVICE LITERATURE MANUAL)
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING
U.S. PATENTS: 4686834 4689967 4715190 5056032
5058031 5434738 5563489 5836382
SERVICE LITERATURE
INSTALLATION, OPERATION AND MAINTENANCE MANUAL:
CVGF-SVN02C-EN AND CVGF-SVU02B-EN
"FOR INSTALLATION REQUIREMENTS, USE ELECTRICAL
CHARACTERISTICS NOT PRODUCT DESCRIPTION"
PRODUCT DESCRIPTION:
MODL CVGF
DSEQ A0
HRTZ 50
CPKW 338
EVBS C
EVTB TE25
EVWP 2
EVCO FLGE
CDBS C
CDTB TE28
CDCO FLGE
CDWA RERE
SPKGEXPS
INSL YES
TRMM TRMS
LCLD CLDC
SRRL 952
PNCO DISC
S.O. NO:
380 VOLTS
50HZ 3PH
338 kW
345- 422 VAC
726 AMPS
1200 AMPS
1200 AMPS
VOLTS-AC HZ PH RLA
380 50
3
50
31.43 FLA
50
1000 WATTS TOTAL
50
1500 VA MAX
ACTUALLY CHARGED
LOW SIDE 15.2 BAR
LOW SIDE 16.7 BAR
5.17 BAR MAX.
BAR
NTON 500
CPIM 940
EFLD WATE
EVWA RERE
CFLD WATE
ORSZ 23
OPTM YES
LANG ENGL
TEST PTR3
MAX
MAX
LRAY LRAD
577
1048
3286
VOLT 380
EVSZ 500
EVWB NM15
CDSZ 500
CDWB NM15
AGLT UL
WVUO YES
SRTY USTR
CVGF-SVX03B-EN