Siemens SIMATIC ET 200SP Manual

Siemens SIMATIC ET 200SP Manual

Digital output module, dq 16x24vdc/0.5a st, 6es7132-6bh01-0baq
Hide thumbs Also See for SIMATIC ET 200SP:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP

  • Page 2 ___________________ Preface ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Connecting ET 200SP Digital output module ___________________ DQ 16x24VDC/0.5A ST Parameters/address space (6ES7132-6BH01-0BA0) ___________________ Interrupts/diagnostic alarms Manual ___________________ Technical specifications ___________________ Parameter data record 09/2017 A5E03574420-AE...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Purpose of the documentation This manual supplements the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). Functions that generally relate to the system are described in this manual. The information provided in this manual and in the system/function manuals supports you in commissioning the system.
  • Page 5 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 6: Table Of Contents

    Table of contents Preface ..............................4 Documentation guide ..........................7 Product overview ..........................12 Properties ..........................12 Connecting ............................14 Wiring and block diagram ...................... 14 Parameters/address space ........................16 Parameters ..........................16 Declaration of parameters ...................... 18 Address space ........................19 Interrupts/diagnostic alarms ........................
  • Page 7: Documentation Guide

    Documentation guide The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Basic information The system manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP.
  • Page 8 You can download the product information free of charge from the Internet (https://support.industry.siemens.com/cs/us/en/view/73021864). Manual Collection ET 200SP The Manual Collection contains the complete documentation on the SIMATIC ET 200SP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (http://support.automation.siemens.com/WW/view/en/84133942).
  • Page 9 ● Manuals, characteristics, operating manuals, certificates ● Product master data You can find "mySupport" - CAx Data in the Internet (http://support.industry.siemens.com/my/ww/en/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus in individual products.
  • Page 10 You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components.
  • Page 11 Documentation guide SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
  • Page 12: Product Overview

    Product overview Properties Article number 6ES7132-6BH01-0BA0 (number in package unit: 1 unit) 6ES7132-6BH01-2BA0 (number in package unit: 10 units) View of the module ① ⑦ Module type and name Function class ② ⑧ LED for diagnostics Color coding module type ③...
  • Page 13 ● Color identification labels ● Reference identification label ● Shield connector See also You can find additional information on the accessories in the system manualET 200SP distributed I/O system. (http://support.automation.siemens.com/WW/view/en/58649293) Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 14: Connecting

    1-wire connection. You can find information on wiring the BaseUnit in the system manual Distributed I/O System ET 200SP (http://support.automation.siemens.com/WW/view/en/58649293). Note The load group of the module must begin with a light-colored BaseUnit. Keep this in mind also during the configuration.
  • Page 15 Connecting 3.1 Wiring and block diagram Wiring: 1-wire connection of actuators The following figure shows the block diagram and an example for the terminal assignment of the digital output module DQ 16×24VDC/0.5A ST on the BaseUnit BU type A0 (1-wire connection).
  • Page 16: Parameters/Address Space

    Parameters/address space Parameters Parameters for DQ 16x24VDC/0.5A ST Specify the module properties with the various parameters in the course of your STEP 7 configuration. The following table lists the configurable parameters. The effective range of the configurable parameters depends on the type of configuration. The following configurations are possible: ●...
  • Page 17 Parameters/address space 4.1 Parameters Parameters Range of values Default Parameter Scope with configuration software, reassign- e.g. STEP 7 (TIA Portal) ment in GSD file GSD file PROFINET IO PROFIBUS DP Reaction to CPU STOP • Turn off Channel Module Turn off Keep last value •...
  • Page 18: Declaration Of Parameters

    You take the potential of the self-assembling voltage buses P1, P2 and AUX from the left neighbor. A potential group ends with the dark-colored BaseUnit, which follows a light-colored BaseUnit or server module in the station configuration. See also ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 19: Address Space

    Parameters/address space 4.3 Address space Address space The module can be configured differently in STEP 7; see following table. Depending on the configuration, additional/different addresses are assigned in the process image output/input. Configuration options of DQ 16x24VDC/0.5A ST You can configure the module with STEP 7 (TIA Portal) or with a GSD file. If you configure the module by means of a GSD file, the configurations are available under various short designations/module names;...
  • Page 20 Parameters/address space 4.3 Address space Address space The following figure shows the assignment of the address space for the DQ 16x24VDC/0.5A ST with value status (Quality Information (QI)). The addresses for the value status are only available if the value status is enabled. Figure 4-1 Address space of DQ 16×24VDC/0.5A ST with value status Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0)
  • Page 21: Interrupts/Diagnostic Alarms

    Interrupts/diagnostic alarms Status and error display LED display DQ 16x24VDC/0.5A ST. ① DIAG (green/red) ② Channel status (green) ③ PWR (green) Figure 5-1 LED display Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 22 Interrupts/diagnostic alarms 5.1 Status and error display Meaning of the LEDs The following tables contain the meaning of the status and error displays. Remedial measures for diagnostic alarms can be found in chapter Diagnostic messages (Page 24). DIAG LED Table 5- 1 DIAG LED fault display DIAG LED Meaning...
  • Page 23: Interrupts

    Interrupts/diagnostic alarms 5.2 Interrupts Interrupts The digital output module DQ 16×24VDC/0.5A ST supports diagnostic interrupts. Diagnostics interrupts The module generates a diagnostic interrupt at the following events: ● Short-circuit ● Wire break ● Parameter assignment error ● Supply voltage missing Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 24: Diagnostic Messages

    Interrupts/diagnostic alarms 5.3 Diagnostic messages Diagnostic messages A diagnostics alarm is generated and the DIAG-LED flashes on the module for each diagnostics event. You can read out the diagnostics alarms, for example, in the diagnostics buffer of the CPU. You can evaluate the error codes with the user program. Note Parallel connection of two outputs For parallel connection of two outputs for redundant control of a load, the channel...
  • Page 25: Technical Specifications

    Technical specifications Technical specifications Technical specifications of the DQ 16×24VDC/0.5A ST Article number 6ES7132-6BH01-0BA0 General information Product type designation DQ 16x24 VDC/0.5 A ST Firmware version V0.0 FW update possible • usable BaseUnits BU type A0 Color code for module-specific color identifica- CC00 tion plate Product function...
  • Page 26 Technical specifications 6.1 Technical specifications Article number 6ES7132-6BH01-0BA0 Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Input current Current consumption, max. 60 mA; without load Output voltage Rated value (DC) 24 V...
  • Page 27 Technical specifications 6.1 Technical specifications Article number 6ES7132-6BH01-0BA0 Output current 0.5 A for signal "1" rated value • 0.1 mA for signal "0" residual current, max. • Output delay with resistive load 50 µs "0" to "1", typ. • 100 µs "1"...
  • Page 28 Technical specifications 6.1 Technical specifications Article number 6ES7132-6BH01-0BA0 Interrupts/diagnostics/status information Diagnostics function Substitute values connectable Alarms Diagnostic alarm • Diagnostic messages Monitoring the supply voltage • Yes; Module-wise Wire-break • Yes; Module-wise Short-circuit to M • Yes; Module-wise Short-circuit to L+ •...
  • Page 29 Technical specifications 6.1 Technical specifications Article number 6ES7132-6BH01-0BA0 Dimensions Width 15 mm Height 73 mm Depth 58 mm Weights Weight, approx. 30 g Safety-related shutdown Note The digital output module DQ 16x24VDC/0.5A ST supports safety-related shutdown in connection with a fail-safe power module F-PM-E 24VDC/8A PPM ST: •...
  • Page 30 Derating trend The following figure show the load current derating with horizontal and vertical mounting positions. Figure 6-1 Load current for mounting position Dimension drawing See manual ET 200SP BaseUnits (http://support.automation.siemens.com/WW/view/en/58532597/133300) Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 31: Parameter Data Record

    Parameter data record Parameter assignment and structure of parameter data record The data record of the module has an identical structure, regardless of whether you configure the module with PROFIBUS DP or PROFINET IO. With data record 128, you can reconfigure the module in your user program regardless of your programming.
  • Page 32 Parameter data record A.1 Parameter assignment and structure of parameter data record Structure of data record 128 Note Channel 0 includes the diagnostics enable for the entire module. Figure A-1 Structure of data record 128 Header information The figure below shows the structure of the header information. Figure A-2 Header information Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0)
  • Page 33 Parameter data record A.1 Parameter assignment and structure of parameter data record Parameters The figure below shows the structure of the parameters for channels 0 to 15. You enable a parameter by setting the corresponding bit to "1". Figure A-3 Structure byte x to x+1 for the channels 0 to 15 Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) Manual, 09/2017, A5E03574420-AE...
  • Page 34 Parameter data record A.1 Parameter assignment and structure of parameter data record Error transferring the data record The module always checks all the values of the transferred data record. Only if all the values were transferred without errors does the module apply the values from the data record. The WRREC instruction for writing data records returns corresponding error codes when errors occur in the STATUS parameter.

Table of Contents