Technical specifications
6.1 Technical specifications
Article number
Supply voltage
Rated value (DC)
permissible range, lower limit (DC)
permissible range, upper limit (DC)
Reverse polarity protection
Input current
Current consumption, max.
Output voltage
Rated value (DC)
Power loss
Power loss, typ.
Address area
Address space per module
Inputs
•
Outputs
•
Hardware configuration
Automatic encoding
Mechanical coding element
•
Selection of BaseUnit for connection variants
1-wire connection
•
2-wire connection
•
3-wire connection
•
4-wire connection
•
Digital outputs
Type of digital output
Number of digital outputs
Current-sinking
Current-sourcing
Short-circuit protection
Response threshold, typ.
•
Open-circuit detection
Limitation of inductive shutdown voltage to
Controlling a digital input
Switching capacity of the outputs
with resistive load, max.
•
on lamp load, max.
•
Load resistance range
lower limit
•
upper limit
•
26
6ES7132-6BH01-0BA0
24 V
19.2 V
28.8 V
Yes
60 mA; without load
24 V
1 W
+ 2 bytes for QI information
2 byte
Yes
Yes
BU type A0
BU type A0 + Potential isolation module
BU type A0 + Potential isolation module
BU type A0 + Potential isolation module
Source output (PNP, current-sourcing)
16
No
Yes
Yes
1 A
Yes
Typ. L+ (-50 V)
Yes
0.5 A
5 W
48 Ω
12 kΩ
Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0)
Manual, 09/2017, A5E03574420-AE