Festo DMSP Series Operating Instructions Manual
Festo DMSP Series Operating Instructions Manual

Festo DMSP Series Operating Instructions Manual

Fluidic muscle
Hide thumbs Also See for DMSP Series:

Advertisement

Quick Links

Fluidic Muscle
DMSP/MAS
en
Operating
instructions
8081494
2018-01f
[8081496]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DMSP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Festo DMSP Series

  • Page 1 Fluidic Muscle DMSP/MAS Operating instructions 8081494 2018-01f [8081496]...
  • Page 2 ............... . . Festo – DMSP/MAS – 2018-01f...
  • Page 3: Table Of Contents

    ............Festo – DMSP/MAS – 2018-01f English...
  • Page 4: Configuration

    DMSP/MAS Documentation on the product For all available product documentation è www.festo.com/pk Configuration DMSP MAS-…-K/O Thread for supply port (only for DMSP) Thread for connecting adapter (only for Connecting thread (only for DMSP) MAS-…-K/O) Connecting flange with press-form sleeve – for MAS-…-MO open on both sides (only for DMSP) –...
  • Page 5: Safety

    • Take into consideration the ambient conditions at the location of use. Qualified personnel Only qualified personnel may perform installation, commissioning, maintenance and disassembly of the product. The qualified personnel must be familiar with installation of pneumatic systems. Festo – DMSP/MAS – 2018-01f English...
  • Page 6: Function

    – Avoid high temperatures (max. +30 °C) • Protect product in storage from damaging influences. Damaging influences include: – corrosive coolant or other materials (e.g. ozone) – oils, greases and grease-solvent vapours – glowing chips or sparks Festo – DMSP/MAS – 2018-01f English...
  • Page 7: Installation

    MAS-10-…-O (without force limiter). Ó Ó Ó Ó • Make sure that the connecting thread lengths of adapter and MAS fit each other Fig. 4 (è Tab. 2). Ó Ó Festo – DMSP/MAS – 2018-01f English...
  • Page 8: Pneumatic Installation

    Pneumatic installation • Connect the compressed air supply: at port 1 – DMSP: – MAS-…-K/O: at adapter (A) Ó Ó Ó Ó Ó Ó Ó Ó Fig. 6 Festo – DMSP/MAS – 2018-01f English...
  • Page 9: Commissioning

    – Contraction takes place within the permissible tolerance (max. 25 % of the nominal length). – The required force is reached/the load is lifted. – No leakage occurs. 3. End the test run. 4. Vent the fluidic muscle. Festo – DMSP/MAS – 2018-01f English...
  • Page 10: Operation

    [%] Fig. 8 • Protect product during operation from damaging influences. These influences include: – corrosive coolant or other materials (e.g. ozone) – oils, greases and grease-solvent vapours – glowing chips or sparks Festo – DMSP/MAS – 2018-01f English...
  • Page 11: Maintenance And Care

    Due to the safety requirements for the connection between the contraction membrane and connecting flange, a repair is not permissible. Disposal • Dispose of packaging and DMSP/MAS at the end of its useful life through environmentally friendly recycling in accordance with applicable specifications. Accessories è www.festo.com/catalogue Festo – DMSP/MAS – 2018-01f English...
  • Page 12: Fault Clearance

    Diaphragm is worn out. Replace DMSP/MAS. DMSP/MAS does not reach Air volume is lacking. Increase connection cross-section. the desired speed. Place volume upstream. Use short tubing lines. Valve is too small. Use a larger valve. Tab. 4 Festo – DMSP/MAS – 2018-01f English...
  • Page 13: Technical Data

    Loctite 243 1) In % of the nominal length (= visible area of the load-free contracting diaphragm) 2) At minimum nominal length, the force is reduced by about 10%. 3) With force compensator Tab. 5 Festo – DMSP/MAS – 2018-01f English...
  • Page 14: Characteristic Curves

    0 bar 1 bar 2 bar 3 bar 4 bar 5 bar 6 bar Max. pretensioning Permissible work space with Max. permissible contraction DMSP-5 Theoretical force (140 N) at max. operating pressure Fig. 9 Festo – DMSP/MAS – 2018-01f English...
  • Page 15 6 bar Max. pretensioning Permissible work space with Max. permissible contraction DMSP/MAS-20 With force limiter at 1200 N Work space with force limiter for Theoretical force (1500 N) at max. operating pressure MAS-20-...-K Fig. 11 Festo – DMSP/MAS – 2018-01f English...
  • Page 16 6 bar Max. pretensioning Permissible work space with Max. permissible contraction DMSP/MAS-40 With force limiter at 4000 N Work space with force limiter for Theoretical force (6000 N) at max. operating pressure MAS-40-...-K Fig. 12 Festo – DMSP/MAS – 2018-01f English...
  • Page 17 DMSP/MAS Festo – DMSP/MAS – 2018-01f...
  • Page 18 Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany Phone: +49 711 347-0 Fax: +49 711 347-2144 Reproduction, distribution or sale of this document or communica­ E-mail: tion of its contents to others without express authorization is service_international@festo.com...

This manual is also suitable for:

Mas-series-k/o

Table of Contents