· 4 analog inputs · 1 analog output Expansion I/O Board 3G3AX-EIO21-RE Board is placed into inverter option slot (see point 3.2 Installing the Expansion I/O Board) . To manage this expansion I/O board, a Drive Programming user program must be running.
11.- Set the inverter parameter A017 to value 1 or 2 to run the Drive Programming program. Now, Drive Prorgamming program is linked and working with the expansion I/O module 3G3AX-EIO21-RE. (*) All new option boards will not work with this new setting (Profibus, devicenet, componet, ethercat).
Expansion I/O Board 3G3AX-EIO21-RE DRIVE PROGRAMMING Dedicated User Parameters Using Expansion I/O Board 3G3AX-EIO21-RE on 3G3RX inveter some Drive Programming internal user parameters are exclusively dedicated. Refer to the next table: Parameters Description Range 0 – 255 U(00) To read the 8 expanded digital input status [from bit 0(IX0) to bit 7(IX7)] 0 –...
Page 7