Safety Regulations And Certifications - Trane CGCN Installation Operation & Maintenance

Indoor air-cooled chillers and heat pumps
Table of Contents

Advertisement

Safety regulations and Certifications

Reference standards
PRESSURE EQUIPMENT DIRECTIVE (97/23/EC).
UNI EN ISO 3744 ACOUSTIC REGULATION.
UNI-EN-ISO 9001:2008: QUALITY MANAGEMENT SYSTEMS
LOW VOLTAGE DIRECTIVE (LVD) 2006/95/EC
MACHINERY DIRECTIVE 2006/42/EC
DIRECTIVE FOR ELECTROMAGNETIC COMPATIBILITY 2004/108/CE.
CEI-EN 60204-1 DIRECTIVE (CEI44-5; CEI EN 62061) MACHINERY SAFETY – ELECTRIC MACHINERY –
EQUIPMENTS
ERP DIRECTIVE (ENERGY-RELATED-PRODUCTS ECODESIGN 2009/125/CE)
UNI EN 14511-1-2-3-4 TESTING CONDITIONS
Certifications
PED RELEASED FROM IMQ SPA - NOTIFIED BODY FOR REGULATION 97/23/EC (NO. 0051) ACCORDING
TO THE FOLLOWING STATEMENTS:
DECLARATION OF QUALITY SYSTEM APPROVAL - FORM H1 (QUALITY ASSURANCE WITH DESIGN
CONTROL AND MONITORING OF FINAL CHECK DETAIL): CERTIFICATE N. PEC-0051-1105003.
CERTIFICATES OF EXAMINATION OF THE PROJECT N. 0051-PEC-1105004/05/06/07/08.
QUALITY CERTIFICATION ACCORDING TO THE STANDARD UNI EN ISO 9001:2008 ISSUED BY CSQ
(ACCREDITED BY ACCREDIA).
PERFORMANCE CERTIFICATION OF THE UNIT WITH THE PRESENCE OF RINA SPA DURING THE
TESTING PROCESS (OPTIONAL).
GOST CERTIFICATION - (OPTIONAL) FOR PRESSURE RECIPIENTS OF THE RUSSIAN FEDERATION.
Definitions
Owner:
The legal representative of the company, body or natural person who owns the plant in which the Trane unit is
installed: he or she is responsible for the control and respect of all the safety regulations indicated in this manual
as well as the national ones in force.
Installer:
The legal representative of the company appointed by the owner to position and hydraulically, electrically etc.
connect the Trane unit to the plant: he or she is responsible for moving and the correct installation of the unit in
accordance with the indications in this manual and with the national regulations in force.
Operator:
A person authorised by the owner to carry out all the operations of regulation and control on the Trane unit which
are specifically mentioned in this manual. He or she should keep to actions described in the manual and limit his or
her action to what is explicitly allowed.
Technician:
A person who is directly authorised by Trane or, secondarily, for all EU countries except for Italy, by the distributor
of the Trane product, under their own responsibility, to carry out all ordinary or extraordinary maintenance
operations, as well as regulations, controls, repairs and parts replacement which may be necessary during the
lifetime of the unit.
Access to dangerous areas
The access to the unit dangerous areas is usually obstructed through protection panels, which are removable, by
using a tool. Axial fans are protected with accident prevention grilles. Centrifugal fans are not protected on the
discharge, as they have to be connected to ducts. In case they have to run without ducts, it is the installer duty to
provide protection grilles.
Finned coil, for units not equipped with coil protection grilles, is completely accessible with danger for cuts and
abrasions. In these cases technicians and operators must be aware about this risk.
For all the units which allow access to the cooling piping or to the packaged condensing coils with fins, without
security gratings (optional) or closing panelling, the following precautions must be taken
mark the areas with contact risks.
apply warning signs.