User Manual Installation Dragon PTN Interface Module PTN-7-SERIAL Installation PTN-7-SERIAL Technical support Release 01 02/2018 https://hirschmann-support.belden.com...
Page 2
In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
Table 2. After the module has gone through all the cycles in the table below (=rebooted successfully), the module turns into the normal operation, see LEDs in Table 3. Installation PTN-7-SERIAL Release 01 02/2018...
RJ.5 connector 2 LEDs show information of serial port 2; etc..RJ.5 connector 8, 9, 10 LEDs are only lit during the self-test in the boot cycle (see Table 2) but have no further meaning. Installation PTN-7-SERIAL Release 01 02/2018...
The Basic kit (order n° 942 256-300) must be used to wire out serial port 1, 2 and 3. This kit includes 5 open end RJ.5 cables of 3 meter marked from 1 to 5. This kit must be connected to connector [15] on the front panel; Installation PTN-7-SERIAL Release 01 02/2018...
Asynchronous: no clock is exchanged between the transmitter and receiver. Only data is exchanged. Both the transmitter and receiver use start and stop bits to indicate the start and stop of data; Installation PTN-7-SERIAL Release 01 02/2018...
When Hitless Switching has been enabled, the CES can only start up with two links up, coming out of a two-links-down situation (except when Single Path has been enabled, see §2.2.10). See §2.2.11 for a delay comparison within CES depending on the enabled sub features, see also further on. Installation PTN-7-SERIAL Release 01 02/2018...
CES starts up according to the slowest path; no CES interrupt or packet loss when the fastest path comes up later on; See §2.2.11 for a delay comparison within CES depending on the enabled sub features, see also further on. Installation PTN-7-SERIAL Release 01 02/2018...
Figure 12 Single Path Disabled 2.2.11 CES: Delay Comparison in CES Features Table 8 Delay Comparison in CES (Features) CES Hitless Switching Single Path Resulting Delay lowest medium highest X = enabled; --- = disabled Installation PTN-7-SERIAL Release 01 02/2018...
Periodic transmit timer expires (Fixed Transmit Timer); Detection of a line termination character (Delimiter: Line Termination Character); Timeout occurs after the last received byte (Delimiter Timeout); See the HiProvision manual for more info: Ref.[1] in Table 1; Installation PTN-7-SERIAL Release 01 02/2018...
The PRC (=Primary Reference Clock) is a very stable high quality clock that can be used as a reference clock delivered via SyncE to the node: A, D = Application ports; B, C = IFM front ports; Installation PTN-7-SERIAL Release 01 02/2018...
‘Internal Clock’ on the IFM. This clock is delivered by the CSM and is based on a PRC delivered via SyncE. NOTE: SyncE: See the manuals in Ref.[1] and Ref.[4] for more detailed information; Installation PTN-7-SERIAL Release 01 02/2018...
The Hardware Edition (labeled as CARD_ED) (see Figure 15) is set in decimal code using rotary switches S2 to S3 (=most significant). It can be read out as well via HiProvision. This edition has been factory set and MUST NOT BE CHANGED! Installation PTN-7-SERIAL Release 01 02/2018...
See ‘jitter buffer’ in the ‘ Dragon PTN and HiProvision Operation’ Manual (=Ref. [1]) for more information. Maximum Network Path Delay Difference (µs) (only for Hitless Switching): advise: Set this value to ‘(Two Paths nodes difference)*10 + expected peak-to-peak jitter (µs)’. If Installation PTN-7-SERIAL Release 01 02/2018...
→ 1-6 TDM frames/packet; if less bandwidth is required and delay is not important → at least 8 TDM frames/packet; if less bandwidth and a small delay are wanted → 8 .. 10 TDM frames/packet. Installation PTN-7-SERIAL Release 01 02/2018...
20.32 mm / 0.8 inches height: 126 mm / 4.96 inches depth: 195 mm / 7.68 inches 4.3 Ordering Information PTN-7-SERIAL: 942 236-014. 5. ABBREVIATIONS BERT Bit Error Ratio Tester Conformité Européenne CESoPSN Circuit Emulation Service over Packet Switched Network...
Page 29
Primary Reference Clock Packet Transport Network Request To Send Remote Terminal Unit Receive Clock Receive Data SCADA Supervisory Control and Data Acquisition SCTE Serial Clock Transmit External Terminal Timing Clock Transmit Data Wide Area Network Installation PTN-7-SERIAL Release 01 02/2018...