Bosch Rexroth AG
Maintenance
The USB flash drive does not function,
although other USB devices function
USB devices and touch screen do not
work
Touch screen functionality is not availa-
ble
Tab. 13-1: Error causes and error elimination
14 Maintenance
14.1 General Information
NOTICE
The IP degree of protection must be ensured during maintenance!
14.2 Tightening torques
NOTICE
If screws were removed because of maintenance works, fasten them again with
the corresponding torque according to the following table.
Threads
M2.5
M3
M4
M5
Tab. 14-1: Mounting torques
14.3 Display
14.3.1 General Information
The backlight is subject to wear, see
A fading backlight causes a progressive deterioration display readability, so that
a replacement is necessary. For further information please contact the Bosch
Rexroth Service.
42/53
VDP 16.3, VDP 40.3, VDP 60.3
Set the DIP switch on the VDP to <30 m
●
Set the DIP switch adequately to the cable length
●
Recalibrate the touch screen
●
Loss of IP degree of protection due to incorrect
maintenance.
Damage of the mechanics caused by wrong
tightening torque.
Mounting torques
0.4 Nm
0.7 Nm
1.4 Nm
2.8 Nm
chapter 5.7 "Wear Parts" on page
8.
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P