VDP 16.3, VDP 40.3, VDP 60.3
Symbol,
Display
LED
LED yellow
LED flashes yel-
HDD
low
LED off
LED flashes red
Temp
LED red
LED off
LED red
UPS
Tab. 12-4: LEDs for operating and error display on the front panel
Depending on the connected control cabinet PC, not all LEDs are ac-
tivated. Therefore not all warnings and messages are displayed.
For further information, please refer to the relevant documentation
of the control cabinet PC.
12.4 Y-Repeater
Two operator displays can be connected to one control cabinet PC using a Y-re-
peater. It cascades up to four operator displays. For more information about the
Y-Repeater, refer to the operating instructions "Rexroth IndraControl VAC 01 Y-
Repeater" (see
tab. 1-1 "Required and supplementing documentation" on page
2).
13 Error Causes and Elimination
The error display on the front panel is described in
Error Displays" on page
Error
No image visible
Wrong display resolution
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P
Meaning
Hard disk access
Warning: SMART analysis identi-
fies errors
Temperature in safe range
Fan in control cabinet does not run
or runs too slow
Temperature > 50 °C
Normal operation
The control cabinet PC is currently
operating in the UPS mode. I.e.,
the supply voltage is not available!
40.
Correction
Connect the supply voltage, check the X1S1 connection
●
Connect the CDI cable correctly, check XVID and XSER
●
Set the screen output in the graphics driver to "VDP"
●
Switch on the voltage at the VDP before or at the same
●
time as the control cabinet PC
Set the correct display resolution in the graphics driver
●
Restart the control cabinet PC
●
Bosch Rexroth AG
Error Causes and Elimination
Measure
-
Exchange hard disk
-
Check the fan in the control cabi-
net PC
Reduce surrounding air tempera-
ture!
-
Restore supply voltage, initiate
controlled restart of the control
cabinet PC!
chapter 12.3 "Operating and
41/53