y= 0 relay
1 ext. siren
2 panic
3 fire
4 arm
5 int. siren
Note: If an output is activated by the [5][xy] command, the output will stay active until you press [
in the installer programming level again.
Example: Enter [5] [02] to activate the panic output, enter [
[8] Optional devices programming
See corresponding device manual for more information when you install such a device. Press [#] to return to normal
installer programming.
[9] Events history output
information about events history to the special serial interface (printer) which can be connected to the keypad terminals
as an option (the same function as in the User programming level [∗][5]).
Note
: Press [#] to return to the standby level from the installer programming level when you finish programming. All
programming is stored in the non voltage memory. Additionally, the current working mode is stored in the non voltage
memory. If power is switched completely off, the control panel will return to the original settings when the power comes
on again.
For example, if the power is switched off completely and an alarm condition is present, the control panel will start in the
alarm condition when the power is switch on again.
If there is any reason to switch the power completely off (for example when you want to extend the system with an
optional device), we recommend to enter the installer programming level at first.
FACTORY DEFAULT SETTING:
Master Code:
Installer Code:
Zone definition:
Timers:
Entry delay:
Alarm duration:
Alarm outputs:
Technical Relay only
Optional functions:
Number of attempts to enter code: 5
Quick arming: disabled
Auto AT HOME arming: disabled
If somebody in: alarm can be adible
COMPLETE RESET:
In the event that the master code or installer code is forgotten (or for some other reason), it is possible to completely
reset all settings of the H-915 to the factory default. To do this, disconnect the power completely (A.C. and back up
battery). Then install the jumper RESET on the control panel board.
Reconnect the power supply. Wait 2 seconds and remove the jumper. The control panel will perform a self test and
end in installer programming mode (press [#] to entr stand by).
WHEN INSTALLATION IS FINISHED:
Explain and demonstrate all the functions of the H-915 system to the users. Be sure that they know how to program the
access codes and how to operate the system.
H-915 installation manual
- for programming of devices which are connected trough serial line.
. If you press [9] in the installer programming level the H-915 control panel will send
1234
1010
No other access codes programmed
1 delay
2 next delay interior
3 interior instant
4 instant
5 instant
6 instant
Exit delay: 40 sec.
20 sec.
3 min.
Fire E.siren, I.siren, Relay, Fire
Intruder E.siren, I.siren, Relay
Panic Panic only
Arming confirmed only by keypad's buzzer
Loop 6 works as zone 6 input
] to switch off this output.
11/9
]. Then you are back
TBT502 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hestia h-915kHestia h-915c

Table of Contents