3. Make sure that the terminals on the battery and the
battery charger are clean before use.
4. Clean around the oil tank cap with a brush.
Keypad
Problem
Green start LED
flashes.
Red error LED flash-
es.
The product does not
start.
Red error LED
comes on.
Battery
LED display
Green activate LED flashing
Error LED flashing
Error LED is lit
Battery charger
Problem
Red error LED flashes.
Red error LED comes on.
783 - 001 - 12.11.2018

Troubleshooting

Possible faults
Low battery voltage.
Overload.
Temperature deviation.
The power trigger and the start button are
pushed at the same time.
Dirt in the battery connectors.
It is necessary to do servicing on the product. Speak to your servicing dealer.
Possible faults
Low battery voltage.
The battery is discharged.
Temperature deviation.
Cell difference is too much (1V).
Possible faults
Temperature deviation.
5. Clean the inner surface of the protective cover with a
brush.
Possible solution
Charge the battery.
The cutting attachment is blocked. stop the
product. Remove the battery. Clean the cut-
ting attachment from unwanted materials.
Loosen the chain.
Let the product become cool.
Release the power trigger and push the start
button.
Clean the battery connectors with com-
pressed air or a soft brush.
Possible action
Charge the battery.
Charge the battery.
Use the battery in surroundings where tem-
peratures are between -10°C (14°F) and
40°C (104°F).
Contact your servicing agent.
Possible solution
Use the battery charger in tempera-
tures between 5 °C (41 °F) and 40 °C
(104 °F).
Speak to your servicing dealer.