BEFORE YOU START
BEFORE INSTALLING PUMP, BE SURE TO READ THIS
OWNER'S MANUAL CAREFULLY.
REFER TO PRODUCT DATA PLATE(S) FOR ADDITIONAL
OPERATING INSTRUCTIONS AND SPECIFICATIONS.
C AU T I O N
Keep work area clean, well-lit and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing
maintenance on pump.
Adhere to the guidelines of the National Electric Code (NEC)
or Canadian Electric Code (CEC), and any other state and local
codes for ALL electrical installations. Check with the
appropriate agencies or contact a licensed electrician.
Most water system problems result from improper installation.
It is suggested that you read this manual carefully
before installing your pump.
Check and make available all the tools you will need to
install your pump. Required tooling may include wrenches,
pipe sealant, pipe fittings and nipples, screwdriver, etc.
Be sure to have available proper and adequate wiring material
to complete the installation correctly.
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see
this symbol on your pump or in the manual, look
for one of the following signal words and be alert
to the potential for personal injury:
warns about hazards that will cause
D A N G E R
serious personal injury, death or major
property damage if ignored.
C1-SERIES CISTERN
OWNER'S MANUAL
WA R N I N G
C AU T I O N
The label NOTICE indicates special instructions, which are
important but not related to hazards.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
WA R N I N G
Do not run pump dry. Pump must be fully submersed in water
prior to starting. If run without water, the pump and motor will
be damaged.
Electrical Safety
C AU T I O N
warns about hazards that can cause
serious personal injury, death or major
property damage if ignored.
warns about hazards that will or can
cause minor personal injury or major
property damage if ignored.
WA R N I N G
HAZARDOUS PRESSURE. Do not run pump
against closed discharge. Release all system
pressure before working on any component.
Under certain conditions, submersible pumps
can develop extremely high pressure. Install
a pressure relief valve, which is capable
of draining the pumps max output at the
relief valves rated pressure.
Make sure all ELECTRICAL POWER IS OFF
before connecting any electrical wires.
WA R N I N G

Advertisement

Table of Contents
loading

Summary of Contents for Franklin Electric C1 SERIES

  • Page 1 C1-SERIES CISTERN OWNER’S MANUAL warns about hazards that can cause WA R N I N G serious personal injury, death or major property damage if ignored. warns about hazards that will or can C AU T I O N cause minor personal injury or major property damage if ignored.
  • Page 3: Inspect Your Shipment

    INSPECT YOUR SHIPMENT AT T E N T I O N All Franklin Electric C1-Series are carefully tested, inspected, and IMPORTANT INFORMATION FOR INSTALLERS OF THIS EQUIPMENT! packaged to insure their arrival in perfect condition. When the THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY pump is received, examine it closely to make sure there is no TECHNICALLY QUALIFIED PERSONNEL.
  • Page 4: Electrical Installation

    ELECTRICAL INSTALLATION Water Supply Requirement The C1-Series is designed to pump water from a cistern holding 1. Employ a licensed electrician to perform the wiring. All wiring tank. The unit should be kept completely full of water at all times. must be done in accordance with applicable national and The system should not be run dry, without water, for even short local electrical codes.
  • Page 5: Installation Records

    Starting INSTALLATION RECORDS Close all system outlets, then slightly crack one system outlet To keep an accurate record of your installation, be sure to fill to allow excess air to bleed out of the system. Start the pump. out the data below: Immediately upon starting, slowly begin opening the discharge valve until half open.
  • Page 6: Appendix 1 - C1 Performance Curves

    APPENDIX 1 - C1 PERFORMANCE CURVES C1 Series Family Curve 10 GPM 20X GPM 20 GPM 30 GPM Flow (gpm)
  • Page 7: Appendix 2 - Friction Loss Tables

    APPENDIX 2 - FRICTION LOSS TABLES Note: Chart shows friction loss per 100’ of pipe. To convert to friction loss per foot, move decimal point two places to the left. 1" 1-1/4" Schedule 40 pipe 1.049 in. i.d. / Type L Copper tube 1.025 in. i.d Schedule 40 pipe 1.380 in.
  • Page 8: Limited Warranty

    THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects in material or workmanship of the Company.

Table of Contents