FBM 75 and 125:
Mark positions of two bottom fixing points (ensure heater is level).
Drill and plug these positions.
Screw in fixing bolts leaving head 5mm from wall.
Locate slotted bottom fixing brackets onto fixing bolts, mark top two
fixing positions.
Remove heater, drill and plug these positions.
Replace heater onto bottom fixing bolts, secure by screwing in top fixing
bolts.
Tighten bottom fixing bolts.
Model
Weight
E mpty Full
kg
FBM25
19 59
FBM50
30 95
FBM75
36 131 1076 610 295
FBM125 48 213 962
G
F
A
kg
mm
mm
682
609 250 657
974
609 250 949
729 429
B
C
D
mm
mm
-
-
E
F
G
mm
mm
mm
-
445 456 84
-
445 456 84
1132 445 456 106
1001 565 590 102
H
mm
3

Advertisement

loading

This manual is also suitable for:

Fbm 50Fbm 25Fbm 125Fbm 75