Atlas Copco GA 30+ Instruction Book page 51

Oil-injected rotary screw compressors
Hide thumbs Also See for GA 30+:
Table of Contents

Advertisement

Instruction book
Starting from the Main screen:
• Press Scroll button (12) until <P.04> is shown and then press Enter button (13). Pressure band 1 (<Pb.
1>) is shown on the display. Button (12) can be used to scroll to pressure band 2 (<Pb.2>).
• Press Enter button (13) on the desired pressure band. The load level of the selected pressure band
appears. Button (12) can be used to scroll to the unload level.
Modification
• Press Enter button (13) to modify the load level (value starts blinking). A password may be required.
Use Scroll buttons (12) to change the loading pressure.
• Press Enter button (13) to program the new values or press the Escape button (14) to cancel.
2920 7180 30
Loading pressure
Unloading pressure
49